ANALYSIS OF THE 1998 WATER-DISTRIBUTION SYSTEM
SERVING THE DOVER TOWNSHIP AREA, NEW JERSEY:
Field Data Collection Activities and
Water Distribution System Modeling
SUPPLEMENTAL DATA
Appendix N:
Graphs and Tables of Measured and Simulated Booster Pump Flows, August 1998

Holiday City Booster Pump: Model Link 20011
| Holiday City Booster Pump Flow, Model Link 20011, August 14-15, 1998 | |||||||||
|
Time
(Hour) |
Simulated
(gpm) |
Measured
(gpm) |
Difference
(gpm) |
ABS Diff
(gpm) |
Time
(Hour) |
Simulated
(gpm) |
Measured
(gpm) |
Difference
(gpm) |
ABS Diff
(gpm) |
|
0:00
|
0.00
|
--
|
--
|
--
|
0:00
|
0.00
|
--
|
--
|
--
|
|
1:00
|
0.00
|
--
|
--
|
--
|
1:00
|
0.00
|
--
|
--
|
--
|
|
2:00
|
0.00
|
--
|
--
|
--
|
2:00
|
0.00
|
--
|
--
|
--
|
|
3:00
|
0.00
|
--
|
--
|
--
|
3:00
|
0.00
|
--
|
--
|
--
|
|
4:00
|
0.00
|
--
|
--
|
--
|
4:00
|
0.00
|
--
|
--
|
--
|
|
5:00
|
0.00
|
--
|
--
|
--
|
5:00
|
0.00
|
--
|
--
|
--
|
|
6:00
|
1307.71
|
--
|
--
|
--
|
6:00
|
1249.51
|
--
|
--
|
--
|
|
7:00
|
1300.67
|
--
|
--
|
--
|
7:00
|
1203.98
|
--
|
--
|
--
|
|
8:00
|
1220.73
|
--
|
--
|
--
|
8:00
|
1246.97
|
--
|
--
|
--
|
|
9:00
|
1153.94
|
--
|
--
|
--
|
9:00
|
1273.98
|
--
|
--
|
--
|
|
10:00
|
0.00
|
--
|
--
|
--
|
10:00
|
1279.35
|
--
|
--
|
--
|
|
11:00
|
0.00
|
--
|
--
|
--
|
11:00
|
0.00
|
--
|
--
|
--
|
|
12:00
|
0.00
|
--
|
--
|
--
|
12:00
|
0.00
|
--
|
--
|
--
|
|
13:00
|
0.00
|
--
|
--
|
--
|
13:00
|
0.00
|
--
|
--
|
--
|
|
14:00
|
0.00
|
--
|
--
|
--
|
14:00
|
0.00
|
--
|
--
|
--
|
|
15:00
|
0.00
|
--
|
--
|
--
|
15:00
|
0.00
|
--
|
--
|
--
|
|
16:00
|
0.00
|
--
|
--
|
--
|
16:00
|
0.00
|
--
|
--
|
--
|
|
17:00
|
0.00
|
--
|
--
|
--
|
17:00
|
0.00
|
--
|
--
|
--
|
|
18:00
|
0.00
|
--
|
--
|
--
|
18:00
|
1189.04
|
--
|
--
|
--
|
|
19:00
|
0.00
|
--
|
--
|
--
|
19:00
|
1154.30
|
--
|
--
|
--
|
|
20:00
|
0.00
|
--
|
--
|
--
|
20:00
|
0.00
|
--
|
--
|
--
|
|
21:00
|
0.00
|
--
|
--
|
--
|
21:00
|
0.00
|
--
|
--
|
--
|
|
22:00
|
0.00
|
--
|
--
|
--
|
22:00
|
0.00
|
--
|
--
|
--
|
|
23:00
|
0.00
|
--
|
--
|
--
|
23:00
|
0.00
|
--
|
--
|
--
|
--, Data not available
Difference (gpm) = [measure flow (gpm) -
simulated flow (gpm)]; ABS Diff = absolute value of difference

Holly Plant Booster Pumps 1,2, and 3: Model Links 20003, 20004, and 20005
| Holly Plant Booster Pumps 1,2, and 3 Flow, Model Links 20003, 20004, and 20005, August 14-15, 1998 | |||||||||
|
Time
(Hour) |
Simulated
(gpm) |
Measured
(gpm) |
Difference
(gpm) |
ABS Diff
(gpm) |
Time
(Hour) |
Simulated
(gpm) |
Measured
(gpm) |
Difference
(gpm) |
ABS Diff
(gpm) |
|
0:00
|
1317.16
|
1328.21
|
11.05
|
11.05
|
0:00
|
1351.68
|
1357.41
|
5.73
|
5.73
|
|
1:00
|
1239.73
|
1305.38
|
65.65
|
65.65
|
1:00
|
1358.62
|
1342.98
|
-15.64
|
15.64
|
|
2:00
|
1395.69
|
1344.66
|
-51.03
|
51.03
|
2:00
|
1431.48
|
1336.60
|
-94.88
|
94.88
|
|
3:00
|
1359.77
|
1380.91
|
21.14
|
21.14
|
3:00
|
1432.60
|
1361.77
|
-70.83
|
70.83
|
|
4:00
|
1612.64
|
1445.69
|
-166.95
|
166.95
|
4:00
|
1520.44
|
1425.89
|
-94.55
|
94.55
|
|
5:00
|
1658.27
|
1816.93
|
158.66
|
158.66
|
5:00
|
1617.56
|
1635.67
|
18.11
|
18.11
|
|
6:00
|
3142.01
|
2925.95
|
-216.06
|
216.06
|
6:00
|
3007.71
|
2618.49
|
-389.22
|
389.22
|
|
7:00
|
3137.37
|
2922.60
|
-214.77
|
214.77
|
7:00
|
2918.64
|
2862.51
|
-56.13
|
56.13
|
|
8:00
|
2984.89
|
2853.79
|
-131.10
|
131.10
|
8:00
|
3026.43
|
2876.61
|
-149.82
|
149.82
|
|
9:00
|
2854.32
|
2817.53
|
-36.79
|
36.79
|
9:00
|
3024.38
|
2823.58
|
-200.80
|
200.80
|
|
10:00
|
2662.70
|
2716.84
|
54.14
|
54.14
|
10:00
|
3045.62
|
2817.20
|
-228.42
|
228.42
|
|
11:00
|
2569.35
|
2669.51
|
100.16
|
100.16
|
11:00
|
3065.93
|
2837.34
|
-228.59
|
228.59
|
|
12:00
|
2644.58
|
2694.01
|
49.43
|
49.43
|
12:00
|
3058.64
|
2859.83
|
-198.81
|
198.81
|
|
13:00
|
2563.82
|
1721.27
|
-842.55
|
842.55
|
13:00
|
3035.15
|
2818.88
|
-216.27
|
216.27
|
|
14:00
|
1341.46
|
1386.28
|
44.82
|
44.82
|
14:00
|
2750.65
|
2143.53
|
-607.12
|
607.12
|
|
15:00
|
1418.59
|
1397.02
|
-21.57
|
21.57
|
15:00
|
2341.93
|
1937.10
|
-404.83
|
404.83
|
|
16:00
|
1404.73
|
1419.84
|
15.11
|
15.11
|
16:00
|
2207.80
|
1988.45
|
-219.35
|
219.35
|
|
17:00
|
1398.22
|
1431.59
|
33.37
|
33.37
|
17:00
|
2507.51
|
2072.03
|
-435.48
|
435.48
|
|
18:00
|
1388.77
|
1386.61
|
-2.16
|
2.16
|
18:00
|
2449.10
|
2039.14
|
-409.96
|
409.96
|
|
19:00
|
1317.87
|
1378.56
|
60.69
|
60.69
|
19:00
|
2427.58
|
1949.18
|
-478.40
|
478.40
|
|
20:00
|
1349.64
|
1361.10
|
11.46
|
11.46
|
20:00
|
2315.77
|
1533.63
|
-782.14
|
782.14
|
|
21:00
|
1220.05
|
1329.22
|
109.17
|
109.17
|
21:00
|
1300.51
|
1352.71
|
52.20
|
52.20
|
|
22:00
|
1379.60
|
1432.60
|
53.00
|
53.00
|
22:00
|
1337.35
|
1344.32
|
6.97
|
6.97
|
|
23:00
|
1306.80
|
1364.46
|
57.66
|
57.66
|
23:00
|
1284.74
|
1348.35
|
63.61
|
63.61
|
Measured data from United Water Toms River, Inc.,
supervisory control and data acquisition system (SCADA) output
Difference (gpm) = [measured flow (gpm)
- simulated flow (gpm)]; ABS Diff = absolute value of difference

Parkway Booster Pumps 1 and 2: Model Links 20022 and 20023
| Parkway Booster Pumps 1 and 2 Flow, Model Links 20022 and 20023, August 14-15, 1998 | |||||||||
|
Time
(Hour) |
Simulated
(gpm) |
Measured
(gpm) |
Difference
(gpm) |
ABS Diff
(gpm) |
Time
(Hour) |
Simulated
(gpm) |
Measured
(gpm) |
Difference
(gpm) |
ABS Diff
(gpm) |
|
0:00
|
0.00
|
0.00
|
0.00
|
0.00
|
0:00
|
0.00
|
0.00
|
0.00
|
0.00
|
|
1:00
|
0.00
|
0.00
|
0.00
|
0.00
|
1:00
|
0.00
|
0.00
|
0.00
|
0.00
|
|
2:00
|
0.00
|
0.00
|
0.00
|
0.00
|
2:00
|
0.00
|
0.00
|
0.00
|
0.00
|
|
3:00
|
0.00
|
0.00
|
0.00
|
0.00
|
3:00
|
0.00
|
0.00
|
0.00
|
0.00
|
|
4:00
|
0.00
|
0.00
|
0.00
|
0.00
|
4:00
|
0.00
|
0.00
|
0.00
|
0.00
|
|
5:00
|
3256.72
|
3591.00
|
334.28
|
334.28
|
5:00
|
3235.61
|
3438.25
|
202.64
|
202.64
|
|
6:00
|
4920.24
|
4942.25
|
22.01
|
22.01
|
6:00
|
4826.79
|
4743.25
|
-83.54
|
83.54
|
|
7:00
|
4911.90
|
4847.75
|
-64.15
|
64.15
|
7:00
|
4741.47
|
4679.00
|
-62.47
|
62.47
|
|
8:00
|
4786.99
|
4664.00
|
-122.99
|
122.99
|
8:00
|
4814.87
|
4792.00
|
-22.87
|
22.87
|
|
9:00
|
4671.82
|
4561.00
|
-110.82
|
110.82
|
9:00
|
4843.04
|
4662.50
|
-180.54
|
180.54
|
|
10:00
|
4480.89
|
4416.00
|
-64.89
|
64.89
|
10:00
|
4862.56
|
4679.25
|
-183.31
|
183.31
|
|
11:00
|
4371.08
|
4018.75
|
-352.33
|
352.33
|
11:00
|
4901.19
|
4583.25
|
-317.94
|
317.94
|
|
12:00
|
2966.48
|
2880.25
|
-86.23
|
86.23
|
12:00
|
3210.21
|
3161.50
|
-48.71
|
48.71
|
|
13:00
|
2895.26
|
2918.25
|
22.99
|
22.99
|
13:00
|
3210.20
|
3550.00
|
339.80
|
339.80
|
|
14:00
|
2977.89
|
2893.25
|
-84.64
|
84.64
|
14:00
|
4591.51
|
4422.25
|
-169.26
|
169.26
|
|
15:00
|
3061.75
|
3000.75
|
-61.00
|
61.00
|
15:00
|
4623.69
|
4388.25
|
-235.44
|
235.44
|
|
16:00
|
3053.90
|
3048.00
|
-5.90
|
5.90
|
16:00
|
4442.62
|
3795.50
|
-647.12
|
647.12
|
|
17:00
|
4579.18
|
4142.25
|
-436.93
|
436.93
|
17:00
|
3174.46
|
3222.25
|
47.79
|
47.79
|
|
18:00
|
4560.60
|
4418.75
|
-141.85
|
141.85
|
18:00
|
3134.71
|
3185.75
|
51.04
|
51.04
|
|
19:00
|
4429.51
|
4339.75
|
-89.76
|
89.76
|
19:00
|
4719.67
|
4186.50
|
-533.17
|
533.17
|
|
20:00
|
4458.03
|
4321.00
|
-137.03
|
137.03
|
20:00
|
4596.08
|
4387.75
|
-208.33
|
208.33
|
|
21:00
|
4209.10
|
2741.25
|
-1467.85
|
1467.85
|
21:00
|
4354.23
|
3426.50
|
-927.73
|
927.73
|
|
22:00
|
0.00
|
0.00
|
0.00
|
0.00
|
22:00
|
2927.97
|
2441.75
|
-486.22
|
486.22
|
|
23:00
|
0.00
|
0.00
|
0.00
|
0.00
|
23:00
|
2872.88
|
1211.50
|
-1661.38
|
1661.38
|
Measured data from United Water Toms River, Inc.,
supervisory control and data acquisition system (SCADA) output
Difference (gpm) = [measured flow (gpm)
- simulated flow (gpm)]; ABS Diff = absolute value of difference

Windsor Booster Pumps 1, 2 and 3: Model Links 20019, 20020, and 20021
| Windsor Booster Pumps 1, 2, and 3 Flow, Model Links 20019, 20020, and 20021, August 14-15, 1998 | |||||||||
|
Time
(Hour) |
Simulated
(gpm) |
Measured
(gpm) |
Difference
(gpm) |
ABS Diff
(gpm) |
Time
(Hour) |
Simulated
(gpm) |
Measured
(gpm) |
Difference
(gpm) |
ABS Diff
(gpm) |
0:00
|
974.36
|
970.70
|
-3.66
|
3.66
|
0:00
|
973.06
|
1024.23
|
51.17
|
51.17
|
|
1:00
|
871.16
|
929.71
|
58.55
|
58.55
|
1:00
|
971.14
|
983.62
|
12.48
|
12.48
|
|
2:00
|
1076.00
|
1003.19
|
-72.81
|
72.81
|
2:00
|
1053.10
|
998.02
|
-55.08
|
55.08
|
|
3:00
|
1011.36
|
1013.90
|
2.54
|
2.54
|
3:00
|
1054.90
|
1040.11
|
-14.79
|
14.79
|
|
4:00
|
1290.37
|
1089.22
|
-201.15
|
201.15
|
4:00
|
1142.35
|
1076.30
|
-66.05
|
66.05
|
|
5:00
|
1359.85
|
1324.42
|
-35.43
|
35.43
|
5:00
|
1275.11
|
1131.31
|
-143.80
|
143.80
|
|
6:00
|
2273.13
|
1996.78
|
-276.35
|
276.35
|
6:00
|
2056.70
|
1898.19
|
-158.51
|
158.51
|
|
7:00
|
2270.24
|
1995.67
|
-274.57
|
274.57
|
7:00
|
1967.65
|
1897.09
|
-70.56
|
70.56
|
|
8:00
|
2131.98
|
1936.59
|
-195.39
|
195.39
|
8:00
|
2084.37
|
1947.67
|
-136.70
|
136.70
|
|
9:00
|
2020.90
|
1915.55
|
-105.35
|
105.35
|
9:00
|
2074.79
|
1963.92
|
-110.87
|
110.87
|
|
10:00
|
1806.65
|
1839.49
|
32.84
|
32.84
|
10:00
|
2099.08
|
1959.85
|
-139.23
|
139.23
|
|
11:00
|
1698.07
|
1817.33
|
119.26
|
119.26
|
11:00
|
2138.84
|
2099.42
|
-39.42
|
39.42
|
|
12:00
|
1752.96
|
1799.98
|
47.02
|
47.02
|
12:00
|
2836.55
|
2398.87
|
-437.68
|
437.68
|
|
13:00
|
2183.68
|
2088.35
|
-95.33
|
95.33
|
13:00
|
2804.42
|
2364.16
|
-440.26
|
440.26
|
|
14:00
|
2149.43
|
2171.05
|
21.62
|
21.62
|
14:00
|
2382.92
|
1909.27
|
-473.65
|
473.65
|
|
15:00
|
2385.66
|
2212.04
|
-173.62
|
173.62
|
15:00
|
1849.79
|
1819.18
|
-30.61
|
30.61
|
|
16:00
|
2302.67
|
2201.33
|
-101.34
|
101.34
|
16:00
|
1639.35
|
1830.99
|
191.64
|
191.64
|
|
17:00
|
2316.67
|
2258.56
|
-58.11
|
58.11
|
17:00
|
2033.28
|
1919.98
|
-113.30
|
113.30
|
|
18:00
|
2254.21
|
2196.16
|
-58.05
|
58.05
|
18:00
|
1946.37
|
1875.67
|
-70.70
|
70.70
|
|
19:00
|
1992.30
|
2119.36
|
127.06
|
127.06
|
19:00
|
1942.34
|
1816.23
|
-126.11
|
126.11
|
|
20:00
|
2085.87
|
2034.07
|
-51.80
|
51.80
|
20:00
|
1112.26
|
996.91
|
-115.35
|
115.35
|
|
21:00
|
1544.55
|
1392.72
|
-151.83
|
151.83
|
21:00
|
1466.30
|
1481.34
|
15.04
|
15.04
|
|
22:00
|
997.84
|
1062.63
|
64.79
|
64.79
|
22:00
|
1501.23
|
1136.48
|
-364.75
|
364.75
|
|
23:00
|
907.34
|
1010.20
|
102.86
|
102.86
|
23:00
|
877.52
|
961.47
|
83.95
|
83.95
|
Measured data from United Water Toms River, Inc.,
supervisory control and data acquisition system (SCADA) output
Difference (gpm) = [measured flow (gpm)
- simulated flow (gpm)]; ABS Diff = absolute value of difference
Appendix O:
Graphs and Tables of Measured and Simulated Well Flows, March 1998

Berkeley Wells 33, 34, 35: Model Nodes 44658, 44660,44662
| Berkeley Wells 33, 34, and 35 Flow, Model Nodes 44568, 44660, and 44662, March 24-25, 1998 | |||||||||
|
Time
(Hour) |
Simulated
(gpm) |
Measured
(gpm) |
Difference
(gpm) |
ABS Diff
(gpm) |
Time
(Hour) |
Simulated
(gpm) |
Measured
(gpm) |
Difference
(gpm) |
ABS Diff
(gpm) |
|
0:00
|
2529.90
|
2529.80
|
-0.10
|
0.10
|
0:00
|
2130.30
|
2130.74
|
0.44
|
0.44
|
|
1:00
|
2084.40
|
2085.30
|
0.90
|
0.90
|
1:00
|
1841.40
|
1840.90
|
-0.50
|
0.50
|
|
2:00
|
1984.50
|
1983.60
|
-0.90
|
0.90
|
2:00
|
5.40
|
4.72
|
-0.68
|
0.68
|
|
3:00
|
2154.60
|
2155.72
|
1.12
|
1.12
|
3:00
|
5.40
|
4.72
|
-0.68
|
0.68
|
|
4:00
|
1890.00
|
1889.19
|
-0.81
|
0.81
|
4:00
|
5.40
|
5.51
|
0.11
|
0.11
|
|
5:00
|
2262.60
|
2263.78
|
1.18
|
1.18
|
5:00
|
2278.80
|
2278.62
|
-0.18
|
0.18
|
|
6:00
|
2446.20
|
2446.07
|
-0.13
|
0.13
|
6:00
|
2508.30
|
2508.23
|
-0.07
|
0.07
|
|
7:00
|
2610.90
|
2611.05
|
0.15
|
0.15
|
7:00
|
2670.30
|
2669.95
|
-0.35
|
0.35
|
|
8:00
|
2700.00
|
2699.59
|
-0.41
|
0.41
|
8:00
|
2678.40
|
2678.50
|
0.10
|
0.10
|
|
9:00
|
2740.50
|
2739.91
|
-0.59
|
0.59
|
9:00
|
2632.50
|
2632.84
|
0.34
|
0.34
|
|
10:00
|
2621.70
|
2622.46
|
0.76
|
0.76
|
10:00
|
2575.80
|
2574.98
|
-0.82
|
0.82
|
|
11:00
|
2492.10
|
2490.93
|
-1.17
|
1.17
|
11:00
|
2470.50
|
2469.16
|
-1.34
|
1.34
|
|
12:00
|
2508.30
|
2508.00
|
-0.30
|
0.30
|
12:00
|
2489.40
|
2489.39
|
-0.01
|
0.01
|
|
13:00
|
2494.80
|
2496.14
|
1.34
|
1.34
|
13:00
|
2583.90
|
2585.17
|
1.27
|
1.27
|
|
14:00
|
2440.80
|
2439.69
|
-1.11
|
1.11
|
14:00
|
2451.60
|
2452.43
|
0.83
|
0.83
|
|
15:00
|
2427.30
|
2427.72
|
0.42
|
0.42
|
15:00
|
2400.30
|
2401.25
|
0.95
|
0.95
|
|
16:00
|
2470.50
|
2470.66
|
0.16
|
0.16
|
16:00
|
2459.70
|
2458.86
|
-0.84
|
0.84
|
|
17:00
|
2546.10
|
2547.37
|
1.27
|
1.27
|
17:00
|
2527.20
|
2528.11
|
0.91
|
0.91
|
|
18:00
|
2484.00
|
2484.62
|
0.62
|
0.62
|
18:00
|
1976.40
|
1977.02
|
0.62
|
0.62
|
|
19:00
|
2438.10
|
2437.48
|
-0.62
|
0.62
|
19:00
|
1927.80
|
1927.57
|
-0.23
|
0.23
|
|
20:00
|
2446.20
|
2445.98
|
-0.22
|
0.22
|
20:00
|
1946.70
|
1945.76
|
-0.94
|
0.94
|
|
21:00
|
2362.50
|
2362.71
|
0.21
|
0.21
|
21:00
|
2359.80
|
2360.09
|
0.29
|
0.29
|
|
22:00
|
2295.00
|
2295.23
|
0.23
|
0.23
|
22:00
|
2289.60
|
2288.89
|
-0.71
|
0.71
|
|
23:00
|
2211.30
|
2211.81
|
0.51
|
0.51
|
23:00
|
2224.80
|
2225.35
|
0.55
|
0.55
|
Measured data from United Water Toms River, Inc.,
supervisory control and data acquisition (SCADA) system output
Difference (gpm) = [measured flow (gpm)
- simulated flow (gpm)]; ABS Diff = absolute value of difference

Parkway Well Field Wells: Model Node 44567
| Parkway Well Field Well Flow, Model Node 44567, March 24-25, 1998 | |||||||||
|
Time
(Hour) |
Simulated
(gpm) |
Measured
(gpm) |
Difference
(gpm) |
ABS Diff
(gpm) |
Time
(Hour) |
Simulated
(gpm) |
Measured
(gpm) |
Difference
(gpm) |
ABS Diff
(gpm) |
|
0:00
|
3160.50
|
--
|
--
|
--
|
0:00
|
2058.00
|
--
|
--
|
--
|
|
1:00
|
2744.00
|
--
|
--
|
--
|
1:00
|
3185.00
|
--
|
--
|
--
|
|
2:00
|
2670.50
|
--
|
--
|
--
|
2:00
|
2254.00
|
--
|
--
|
--
|
|
3:00
|
1470.00
|
--
|
--
|
--
|
3:00
|
2156.00
|
--
|
--
|
--
|
|
4:00
|
1421.00
|
--
|
--
|
--
|
4:00
|
0.00
|
--
|
--
|
--
|
|
5:00
|
0.00
|
--
|
--
|
--
|
5:00
|
1617.00
|
--
|
--
|
--
|
|
6:00
|
1176.00
|
--
|
--
|
--
|
6:00
|
2450.00
|
--
|
--
|
--
|
|
7:00
|
2303.00
|
--
|
--
|
--
|
7:00
|
2450.00
|
--
|
--
|
--
|
|
8:00
|
2891.00
|
--
|
--
|
--
|
8:00
|
2450.00
|
--
|
--
|
--
|
|
9:00
|
2499.00
|
--
|
--
|
--
|
9:00
|
2744.00
|
--
|
--
|
--
|
|
10:00
|
2597.00
|
--
|
--
|
--
|
10:00
|
2744.00
|
--
|
--
|
--
|
|
11:00
|
2793.00
|
--
|
--
|
--
|
11:00
|
2548.00
|
--
|
--
|
--
|
|
12:00
|
2450.00
|
--
|
--
|
--
|
12:00
|
2646.00
|
--
|
--
|
--
|
|
13:00
|
3087.00
|
--
|
--
|
--
|
13:00
|
3038.00
|
--
|
--
|
--
|
|
14:00
|
2719.50
|
--
|
--
|
--
|
14:00
|
2744.00
|
--
|
--
|
--
|
|
15:00
|
2719.50
|
--
|
--
|
--
|
15:00
|
2744.00
|
--
|
--
|
--
|
|
16:00
|
2719.50
|
--
|
--
|
--
|
16:00
|
3087.00
|
--
|
--
|
--
|
|
17:00
|
2744.00
|
--
|
--
|
--
|
17:00
|
2744.00
|
--
|
--
|
--
|
|
18:00
|
2744.00
|
--
|
--
|
--
|
18:00
|
2744.00
|
--
|
--
|
--
|
|
19:00
|
2744.00
|
--
|
--
|
--
|
19:00
|
2744.00
|
--
|
--
|
--
|
|
20:00
|
3111.50
|
--
|
--
|
--
|
20:00
|
2744.00
|
--
|
--
|
--
|
|
21:00
|
2793.00
|
--
|
--
|
--
|
21:00
|
2744.00
|
--
|
--
|
--
|
|
22:00
|
3038.00
|
--
|
--
|
--
|
22:00
|
3038.00
|
--
|
--
|
--
|
|
23:00
|
2940.00
|
--
|
--
|
--
|
23:00
|
3038.00
|
--
|
--
|
--
|
--, Data not available
Difference (gpm) = [measured flow (gpm)
- simulated flow (gpm)]; ABS Diff = absolute value of difference

Route 70:, Well 31: Model Node 44322
| Route 70 Well 31 Flow, Model Node 44322, March 24-25, 1998 | |||||||||
|
Time
(Hour) |
Simulated
(gpm) |
Measured
(gpm) |
Difference
(gpm) |
ABS Diff
(gpm) |
Time
(Hour) |
Simulated
(gpm) |
Measured
(gpm) |
Difference
(gpm) |
ABS Diff
(gpm) |
|
0:00
|
784.00
|
777.39
|
-6.61
|
6.61
|
0:00
|
782.60
|
775.78
|
-6.82
|
6.82
|
|
1:00
|
2.10
|
2.42
|
0.32
|
0.32
|
1:00
|
2.10
|
2.42
|
0.32
|
0.32
|
|
2:00
|
711.20
|
704.89
|
-6.31
|
6.31
|
2:00
|
2.10
|
2.42
|
0.32
|
0.32
|
|
3:00
|
800.10
|
793.50
|
-6.60
|
6.60
|
3:00
|
2.10
|
2.42
|
0.32
|
0.32
|
|
4:00
|
807.80
|
800.75
|
-7.05
|
7.05
|
4:00
|
1.40
|
1.61
|
0.21
|
0.21
|
|
5:00
|
823.90
|
816.86
|
-7.04
|
7.04
|
5:00
|
711.20
|
704.89
|
-6.31
|
6.31
|
|
6:00
|
758.80
|
752.42
|
-6.38
|
6.38
|
6:00
|
714.70
|
708.92
|
-5.78
|
5.78
|
|
7:00
|
703.50
|
697.64
|
-5.86
|
5.86
|
7:00
|
756.00
|
749.19
|
-6.81
|
6.81
|
|
8:00
|
735.70
|
729.05
|
-6.65
|
6.65
|
8:00
|
747.60
|
741.14
|
-6.46
|
6.46
|
|
9:00
|
797.30
|
790.28
|
-7.02
|
7.02
|
9:00
|
758.80
|
752.42
|
-6.38
|
6.38
|
|
10:00
|
810.60
|
803.97
|
-6.63
|
6.63
|
10:00
|
757.40
|
750.81
|
-6.59
|
6.59
|
|
11:00
|
788.20
|
781.42
|
-6.78
|
6.78
|
11:00
|
749.70
|
743.56
|
-6.14
|
6.14
|
|
12:00
|
747.60
|
741.14
|
-6.46
|
6.46
|
12:00
|
711.90
|
705.69
|
-6.21
|
6.21
|
|
13:00
|
801.50
|
794.31
|
-7.19
|
7.19
|
13:00
|
753.90
|
747.58
|
-6.32
|
6.32
|
|
14:00
|
777.70
|
770.95
|
-6.75
|
6.75
|
14:00
|
824.60
|
817.67
|
-6.93
|
6.93
|
|
15:00
|
733.60
|
727.44
|
-6.16
|
6.16
|
15:00
|
773.50
|
766.92
|
-6.58
|
6.58
|
|
16:00
|
734.30
|
728.25
|
-6.05
|
6.05
|
16:00
|
782.60
|
775.78
|
-6.82
|
6.82
|
|
17:00
|
716.80
|
710.53
|
-6.27
|
6.27
|
17:00
|
697.20
|
691.19
|
-6.01
|
6.01
|
|
18:00
|
785.40
|
779.00
|
-6.40
|
6.40
|
18:00
|
731.50
|
725.03
|
-6.47
|
6.47
|
|
19:00
|
738.50
|
732.28
|
-6.22
|
6.22
|
19:00
|
777.00
|
770.14
|
-6.86
|
6.86
|
|
20:00
|
773.50
|
766.92
|
-6.58
|
6.58
|
20:00
|
779.10
|
772.56
|
-6.54
|
6.54
|
|
21:00
|
739.90
|
733.89
|
-6.01
|
6.01
|
21:00
|
763.00
|
756.44
|
-6.56
|
6.56
|
|
22:00
|
742.00
|
735.50
|
-6.50
|
6.50
|
22:00
|
743.40
|
737.11
|
-6.29
|
6.29
|
|
23:00
|
791.70
|
784.64
|
-7.06
|
7.06
|
23:00
|
782.60
|
775.78
|
-6.82
|
6.82
|
Measured data from United Water Toms River, Inc.,
supervisory control and data acquisition (SCADA) system output
Difference (gpm) = [measured flow (gpm)
- simulated flow (gpm)]; ABS Diff = absolute value of difference

South Toms River: wells 32, 38: Model Nodes 44656, 44664
| South Toms River Wells 32 and 38 Flow, Model Nodes 44656 and 44664, March 24-25, 1998 | |||||||||
|
Time
(Hour) |
Simulated
(gpm) |
Measured
(gpm) |
Difference
(gpm) |
ABS Diff
(gpm) |
Time
(Hour) |
Simulated
(gpm) |
Measured
(gpm) |
Difference
(gpm) |
ABS Diff
(gpm) |
|
0:00
|
546.70
|
542.29
|
-4.41
|
4.41
|
0:00
|
478.80
|
474.62
|
-4.18
|
4.18
|
|
1:00
|
482.30
|
478.38
|
-3.92
|
3.92
|
1:00
|
401.80
|
398.50
|
-3.30
|
3.30
|
|
2:00
|
476.70
|
472.74
|
-3.96
|
3.96
|
2:00
|
0.00
|
1.88
|
1.88
|
1.88
|
|
3:00
|
511.70
|
507.52
|
-4.18
|
4.18
|
3:00
|
0.00
|
1.88
|
1.88
|
1.88
|
|
4:00
|
427.70
|
423.87
|
-3.83
|
3.83
|
4:00
|
0.00
|
1.88
|
1.88
|
1.88
|
|
5:00
|
514.50
|
510.34
|
-4.16
|
4.16
|
5:00
|
573.30
|
568.61
|
-4.69
|
4.69
|
|
6:00
|
559.30
|
554.51
|
-4.79
|
4.79
|
6:00
|
570.50
|
565.79
|
-4.71
|
4.71
|
|
7:00
|
576.10
|
571.43
|
-4.67
|
4.67
|
7:00
|
578.20
|
573.31
|
-4.89
|
4.89
|
|
8:00
|
602.00
|
596.80
|
-5.20
|
5.20
|
8:00
|
573.30
|
568.61
|
-4.69
|
4.69
|
|
9:00
|
571.90
|
566.73
|
-5.17
|
5.17
|
9:00
|
597.10
|
592.11
|
-4.99
|
4.99
|
|
10:00
|
558.60
|
553.57
|
-5.03
|
5.03
|
10:00
|
550.90
|
546.05
|
-4.85
|
4.85
|
|
11:00
|
569.80
|
564.85
|
-4.95
|
4.95
|
11:00
|
556.50
|
551.69
|
-4.81
|
4.81
|
|
12:00
|
535.50
|
531.02
|
-4.48
|
4.48
|
12:00
|
534.80
|
530.08
|
-4.72
|
4.72
|
|
13:00
|
501.20
|
497.18
|
-4.02
|
4.02
|
13:00
|
525.00
|
520.68
|
-4.32
|
4.32
|
|
14:00
|
511.70
|
507.52
|
-4.18
|
4.18
|
14:00
|
553.00
|
547.93
|
-5.07
|
5.07
|
|
15:00
|
532.00
|
527.26
|
-4.74
|
4.74
|
15:00
|
522.20
|
517.86
|
-4.34
|
4.34
|
|
16:00
|
521.50
|
516.92
|
-4.58
|
4.58
|
16:00
|
527.80
|
523.50
|
-4.30
|
4.30
|
|
17:00
|
527.10
|
522.56
|
-4.54
|
4.54
|
17:00
|
559.30
|
554.51
|
-4.79
|
4.79
|
|
18:00
|
533.40
|
529.14
|
-4.26
|
4.26
|
18:00
|
538.30
|
533.83
|
-4.47
|
4.47
|
|
19:00
|
536.90
|
531.95
|
-4.95
|
4.95
|
19:00
|
546.00
|
541.35
|
-4.65
|
4.65
|
|
20:00
|
551.60
|
546.99
|
-4.61
|
4.61
|
20:00
|
550.90
|
546.05
|
-4.85
|
4.85
|
|
21:00
|
537.60
|
532.89
|
-4.71
|
4.71
|
21:00
|
556.50
|
551.69
|
-4.81
|
4.81
|
|
22:00
|
497.70
|
493.42
|
-4.28
|
4.28
|
22:00
|
489.30
|
484.96
|
-4.34
|
4.34
|
|
23:00
|
470.40
|
466.17
|
-4.23
|
4.23
|
23:00
|
487.90
|
484.02
|
-3.88
|
3.88
|
Measured data from United Water Toms River, Inc.,
supervisory control and data acquisition (SCADA) system output
Difference (gpm) = [measured flow (gpm)
- simulated flow (gpm)]; ABS Diff = absolute value of difference
Appendix P:
Graphs and Tables of Measured and Simulated Well Flows, August1998

South Toms River Wells 32, 38, Model Nodes 44656, 44664
| Berkeley Wells 33, 34, and 35 Flow, Model Nodes 44658, 44660, and 44662, August 14-15, 1998 | |||||||||
|
Time
(Hour) |
Simulated
(gpm) |
Measured
(gpm) |
Difference
(gpm) |
ABS Diff
(gpm) |
Time
(Hour) |
Simulated
(gpm) |
Measured
(gpm) |
Difference
(gpm) |
ABS Diff
(gpm) |
|
0:00
|
2151.80
|
2151.41
|
-0.39
|
0.39
|
0:00
|
2212.80
|
2213.01
|
0.21
|
0.21
|
|
1:00
|
2088.00
|
2087.82
|
-0.18
|
0.18
|
1:00
|
2108.50
|
2108.87
|
0.37
|
0.37
|
|
2:00
|
2166.30
|
2166.55
|
0.25
|
0.25
|
2:00
|
2150.70
|
2150.80
|
0.10
|
0.10
|
|
3:00
|
2213.90
|
2213.35
|
-0.55
|
0.55
|
3:00
|
2239.80
|
2239.65
|
-0.15
|
0.15
|
|
4:00
|
2375.90
|
2376.00
|
0.10
|
0.10
|
4:00
|
2359.60
|
2360.30
|
0.70
|
0.70
|
|
5:00
|
2576.70
|
2575.91
|
-0.79
|
0.79
|
5:00
|
2563.10
|
2563.15
|
0.05
|
0.05
|
|
6:00
|
2781.90
|
2781.66
|
-0.24
|
0.24
|
6:00
|
2664.70
|
2664.35
|
-0.35
|
0.35
|
|
7:00
|
2767.40
|
2767.49
|
0.09
|
0.09
|
7:00
|
2702.50
|
2702.45
|
-0.05
|
0.05
|
|
8:00
|
2749.50
|
2749.43
|
-0.07
|
0.07
|
8:00
|
2756.50
|
2756.59
|
0.09
|
0.09
|
|
9:00
|
2690.10
|
2690.95
|
0.85
|
0.85
|
9:00
|
2695.40
|
2695.47
|
0.07
|
0.07
|
|
10:00
|
2522.70
|
2523.67
|
0.97
|
0.97
|
10:00
|
2662.00
|
2662.37
|
0.37
|
0.37
|
|
11:00
|
2435.30
|
2435.26
|
-0.04
|
0.04
|
11:00
|
2565.10
|
2562.14
|
-2.96
|
2.96
|
|
12:00
|
2417.40
|
2417.79
|
0.39
|
0.39
|
12:00
|
2612.40
|
2611.87
|
-0.53
|
0.53
|
|
13:00
|
2428.20
|
2428.87
|
0.67
|
0.67
|
13:00
|
2537.80
|
2538.35
|
0.55
|
0.55
|
|
14:00
|
2368.80
|
2369.67
|
0.87
|
0.87
|
14:00
|
2404.50
|
2404.61
|
0.11
|
0.11
|
|
15:00
|
2436.30
|
2436.00
|
-0.30
|
0.30
|
15:00
|
2421.70
|
2422.39
|
0.69
|
0.69
|
|
16:00
|
2447.10
|
2447.27
|
0.17
|
0.17
|
16:00
|
2467.60
|
2467.17
|
-0.43
|
0.43
|
|
17:00
|
2487.60
|
2487.23
|
-0.37
|
0.37
|
17:00
|
2590.80
|
2590.87
|
0.07
|
0.07
|
|
18:00
|
2425.50
|
2425.45
|
-0.05
|
0.05
|
18:00
|
2556.70
|
2556.23
|
-0.47
|
0.47
|
|
19:00
|
2368.80
|
2369.54
|
0.74
|
0.74
|
19:00
|
2456.80
|
2457.00
|
0.20
|
0.20
|
|
20:00
|
2266.20
|
2266.44
|
0.24
|
0.24
|
20:00
|
2372.10
|
2371.95
|
-0.15
|
0.15
|
|
21:00
|
2220.30
|
2220.45
|
0.15
|
0.15
|
21:00
|
2285.70
|
2286.05
|
0.35
|
0.35
|
|
22:00
|
2385.00
|
2384.40
|
-0.60
|
0.60
|
22:00
|
2259.70
|
2259.75
|
0.05
|
0.05
|
|
23:00
|
2298.60
|
2298.79
|
0.19
|
0.19
|
23:00
|
2238.10
|
2238.46
|
0.36
|
0.36
|
Measured data from United Water Toms River, Inc.,
supervisory control and data acquisition (SCADA) system output
Difference (gpm) = [measured flow (gpm)
- simulated flow (gpm)]; ABS Diff = absolute value of difference

Holly Plant Well 30: Model Node: 55002
| Holly Plant Well 30 Flow, Model Node 55002, August 14-15, 1998 | |||||||||
|
Time
(Hour) |
Simulated
(gpm) |
Measured
(gpm) |
Difference
(gpm) |
ABS Diff
(gpm) |
Time
(Hour) |
Simulated
(gpm) |
Measured
(gpm) |
Difference
(gpm) |
ABS Diff
(gpm) |
|
0:00
|
1680.00
|
--
|
--
|
--
|
0:00
|
1841.70
|
--
|
--
|
--
|
|
1:00
|
1841.70
|
--
|
--
|
--
|
1:00
|
1841.70
|
--
|
--
|
--
|
|
2:00
|
1680.00
|
--
|
--
|
--
|
2:00
|
1995.00
|
--
|
--
|
--
|
|
3:00
|
1890.00
|
--
|
--
|
--
|
3:00
|
1995.00
|
--
|
--
|
--
|
|
4:00
|
1890.00
|
--
|
--
|
--
|
4:00
|
1785.00
|
--
|
--
|
--
|
|
5:00
|
2100.00
|
--
|
--
|
--
|
5:00
|
1785.00
|
--
|
--
|
--
|
|
6:00
|
1890.00
|
--
|
--
|
--
|
6:00
|
2100.00
|
--
|
--
|
--
|
|
7:00
|
1890.00
|
--
|
--
|
--
|
7:00
|
2100.00
|
--
|
--
|
--
|
|
8:00
|
1890.00
|
--
|
--
|
--
|
8:00
|
1890.00
|
--
|
--
|
--
|
|
9:00
|
1890.00
|
--
|
--
|
--
|
9:00
|
1890.00
|
--
|
--
|
--
|
|
10:00
|
1890.00
|
--
|
--
|
--
|
10:00
|
1841.70
|
--
|
--
|
--
|
|
11:00
|
1050.00
|
--
|
--
|
--
|
11:00
|
1841.70
|
--
|
--
|
--
|
|
12:00
|
2100.00
|
--
|
--
|
--
|
12:00
|
1841.70
|
--
|
--
|
--
|
|
13:00
|
1470.00
|
--
|
--
|
--
|
13:00
|
2100.00
|
--
|
--
|
--
|
|
14:00
|
1470.00
|
--
|
--
|
--
|
14:00
|
1785.00
|
--
|
--
|
--
|
|
15:00
|
2100.00
|
--
|
--
|
--
|
15:00
|
1785.00
|
--
|
--
|
--
|
|
16:00
|
1365.00
|
--
|
--
|
--
|
16:00
|
1785.00
|
--
|
--
|
--
|
|
17:00
|
1365.00
|
--
|
--
|
--
|
17:00
|
1785.00
|
--
|
--
|
--
|
|
18:00
|
1785.00
|
--
|
--
|
--
|
18:00
|
1785.00
|
--
|
--
|
--
|
|
19:00
|
1785.00
|
--
|
--
|
--
|
19:00
|
1785.00
|
--
|
--
|
--
|
|
20:00
|
1785.00
|
--
|
--
|
--
|
20:00
|
1785.00
|
--
|
--
|
--
|
|
21:00
|
1785.00
|
--
|
--
|
--
|
21:00
|
1785.00
|
--
|
--
|
--
|
|
22:00
|
1785.00
|
--
|
--
|
--
|
22:00
|
1785.00
|
--
|
--
|
--
|
|
23:00
|
1785.00
|
--
|
--
|
--
|
23:00
|
1785.00
|
--
|
--
|
--
|
--, Data not available
Difference (gpm) = [measured flow (gpm)
- simulated flow (gpm)]; ABS Diff = absolute value of difference

Holly Plant Well 37: Model Node 55003
| Holly Plant Well 37 Flow, Model Node 55003 | |||||||||
|
Time
(Hour) |
Simulated
(gpm) |
Measured
(gpm) |
Difference
(gpm) |
ABS Diff
(gpm) |
Time
(Hour) |
Simulated
(gpm) |
Measured
(gpm) |
Difference
(gpm) |
ABS Diff
(gpm) |
|
0:00
|
0.00
|
--
|
--
|
--
|
0:00
|
0.00
|
--
|
--
|
--
|
|
1:00
|
0.00
|
--
|
--
|
--
|
1:00
|
0.00
|
--
|
--
|
--
|
|
2:00
|
0.00
|
--
|
--
|
--
|
2:00
|
0.00
|
--
|
--
|
--
|
|
3:00
|
0.00
|
--
|
--
|
--
|
3:00
|
0.00
|
--
|
--
|
--
|
|
4:00
|
0.00
|
--
|
--
|
--
|
4:00
|
0.00
|
--
|
--
|
--
|
|
5:00
|
0.00
|
--
|
--
|
--
|
5:00
|
0.00
|
--
|
--
|
--
|
|
6:00
|
0.00
|
--
|
--
|
--
|
6:00
|
0.00
|
--
|
--
|
--
|
|
7:00
|
0.00
|
--
|
--
|
--
|
7:00
|
0.00
|
--
|
--
|
--
|
|
8:00
|
0.00
|
--
|
--
|
--
|
8:00
|
0.00
|
--
|
--
|
--
|
|
9:00
|
0.00
|
--
|
--
|
--
|
9:00
|
0.00
|
--
|
--
|
--
|
|
10:00
|
0.00
|
--
|
--
|
--
|
10:00
|
0.00
|
--
|
--
|
--
|
|
11:00
|
0.00
|
--
|
--
|
--
|
11:00
|
0.00
|
--
|
--
|
--
|
|
12:00
|
0.00
|
--
|
--
|
--
|
12:00
|
0.00
|
--
|
--
|
--
|
|
13:00
|
0.00
|
--
|
--
|
--
|
13:00
|
0.00
|
--
|
--
|
--
|
|
14:00
|
0.00
|
--
|
--
|
--
|
14:00
|
541.80
|
--
|
--
|
--
|
|
15:00
|
0.00
|
--
|
--
|
--
|
15:00
|
541.80
|
--
|
--
|
--
|
|
16:00
|
0.00
|
--
|
--
|
--
|
16:00
|
541.80
|
--
|
--
|
--
|
|
17:00
|
0.00
|
--
|
--
|
--
|
17:00
|
541.80
|
--
|
--
|
--
|
|
18:00
|
0.00
|
--
|
--
|
--
|
18:00
|
541.80
|
--
|
--
|
--
|
|
19:00
|
0.00
|
--
|
--
|
--
|
19:00
|
541.80
|
--
|
--
|
--
|
|
20:00
|
0.00
|
--
|
--
|
--
|
20:00
|
541.80
|
--
|
--
|
--
|
|
21:00
|
0.00
|
--
|
--
|
--
|
21:00
|
541.80
|
--
|
--
|
--
|
|
22:00
|
0.00
|
--
|
--
|
--
|
22:00
|
541.80
|
--
|
--
|
--
|
|
23:00
|
0.00
|
--
|
--
|
--
|
23:00
|
541.80
|
--
|
--
|
--
|
--, Data not available
Difference (gpm) = [measured flow (gpm)
- simulated flow (gpm)]; ABS Diff = absolute value of difference

Parkway Well Field Wells: Model Node 44567
| Parkway Well Field Wells Flow, Model Node 44567, August 14-15, 1998 | |||||||||
|
Time
(Hour) |
Simulated
(gpm) |
Measured
(gpm) |
Difference
(gpm) |
ABS Diff
(gpm) |
Time
(Hour) |
Simulated
(gpm) |
Measured
(gpm) |
Difference
(gpm) |
ABS Diff
(gpm) |
|
0:00
|
0.0
|
--
|
--
|
--
|
0:00
|
0.0
|
--
|
--
|
--
|
|
1:00
|
0.0
|
--
|
--
|
--
|
1:00
|
0.0
|
--
|
--
|
--
|
|
2:00
|
0.0
|
--
|
--
|
--
|
2:00
|
0.0
|
--
|
--
|
--
|
|
3:00
|
0.0
|
--
|
--
|
--
|
3:00
|
0.0
|
--
|
--
|
--
|
|
4:00
|
0.0
|
--
|
--
|
--
|
4:00
|
0.0
|
--
|
--
|
--
|
|
5:00
|
1274.0
|
--
|
--
|
--
|
5:00
|
1136.8
|
--
|
--
|
--
|
|
6:00
|
3699.5
|
--
|
--
|
--
|
6:00
|
3185.0
|
--
|
--
|
--
|
|
7:00
|
3699.5
|
--
|
--
|
--
|
7:00
|
3675.0
|
--
|
--
|
--
|
|
8:00
|
3699.5
|
--
|
--
|
--
|
8:00
|
3920.0
|
--
|
--
|
--
|
|
9:00
|
3699.5
|
--
|
--
|
--
|
9:00
|
4165.0
|
--
|
--
|
--
|
|
10:00
|
3699.5
|
--
|
--
|
--
|
10:00
|
3675.0
|
--
|
--
|
--
|
|
11:00
|
3699.5
|
--
|
--
|
--
|
11:00
|
3675.0
|
--
|
--
|
--
|
|
12:00
|
4067.0
|
--
|
--
|
--
|
12:00
|
3920.0
|
--
|
--
|
--
|
|
13:00
|
4067.0
|
--
|
--
|
--
|
13:00
|
3920.0
|
--
|
--
|
--
|
|
14:00
|
3920.0
|
--
|
--
|
--
|
14:00
|
3675.0
|
--
|
--
|
--
|
|
15:00
|
3675.0
|
--
|
--
|
--
|
15:00
|
3675.0
|
--
|
--
|
--
|
|
16:00
|
3675.0
|
--
|
--
|
--
|
16:00
|
3675.0
|
--
|
--
|
--
|
|
17:00
|
4410.0
|
--
|
--
|
--
|
17:00
|
4165.0
|
--
|
--
|
--
|
|
18:00
|
3920.0
|
--
|
--
|
--
|
18:00
|
4165.0
|
--
|
--
|
--
|
|
19:00
|
3675.0
|
--
|
--
|
--
|
19:00
|
4655.0
|
--
|
--
|
--
|
|
20:00
|
3675.0
|
--
|
--
|
--
|
20:00
|
4165.0
|
--
|
--
|
--
|
|
21:00
|
3920.0
|
--
|
--
|
--
|
21:00
|
4718.7
|
--
|
--
|
--
|
|
22:00
|
4248.3
|
--
|
--
|
--
|
22:00
|
4718.7
|
--
|
--
|
--
|
|
23:00
|
2205.0
|
--
|
--
|
--
|
23:00
|
4410.0
|
--
|
--
|
--
|
--, Data not available
Difference (gpm) = [measured flow (gpm)
- simulated flow (gpm)]; ABS Diff = absolute value of difference

Route 70, Well 31: Model Node 44322
| Route 70 Well 31 Flow, Model Node 44322, August 14-15, 1998 | |||||||||
|
Time
(Hour) |
Simulated
(gpm) |
Measured
(gpm) |
Difference
(gpm) |
ABS Diff
(gpm) |
Time
(Hour) |
Simulated
(gpm) |
Measured
(gpm) |
Difference
(gpm) |
ABS Diff
(gpm) |
|
0:00
|
677.60
|
677.26
|
-0.34
|
0.34
|
0:00
|
711.20
|
711.55
|
0.35
|
0.35
|
|
1:00
|
649.60
|
649.47
|
-0.13
|
0.13
|
1:00
|
683.20
|
683.44
|
0.24
|
0.24
|
|
2:00
|
705.60
|
705.52
|
-0.08
|
0.08
|
2:00
|
716.10
|
715.87
|
-0.23
|
0.23
|
|
3:00
|
718.90
|
719.11
|
0.21
|
0.21
|
3:00
|
761.60
|
761.57
|
-0.03
|
0.03
|
|
4:00
|
723.80
|
724.20
|
0.40
|
0.40
|
4:00
|
762.30
|
762.19
|
-0.11
|
0.11
|
|
5:00
|
732.90
|
733.16
|
0.26
|
0.26
|
5:00
|
770.00
|
769.76
|
-0.24
|
0.24
|
|
6:00
|
744.10
|
744.28
|
0.18
|
0.18
|
6:00
|
785.40
|
785.66
|
0.26
|
0.26
|
|
7:00
|
763.70
|
763.58
|
-0.12
|
0.12
|
7:00
|
762.30
|
762.50
|
0.20
|
0.20
|
|
8:00
|
737.10
|
737.17
|
0.07
|
0.07
|
8:00
|
754.60
|
754.47
|
-0.13
|
0.13
|
|
9:00
|
725.90
|
726.21
|
0.31
|
0.31
|
9:00
|
765.80
|
765.59
|
-0.21
|
0.21
|
|
10:00
|
698.60
|
698.73
|
0.13
|
0.13
|
10:00
|
732.90
|
732.70
|
-0.20
|
0.20
|
|
11:00
|
704.90
|
705.21
|
0.31
|
0.31
|
11:00
|
752.50
|
752.77
|
0.27
|
0.27
|
|
12:00
|
691.60
|
691.78
|
0.18
|
0.18
|
12:00
|
774.90
|
774.70
|
-0.20
|
0.20
|
|
13:00
|
683.20
|
683.29
|
0.09
|
0.09
|
13:00
|
752.50
|
752.46
|
-0.04
|
0.04
|
|
14:00
|
711.20
|
711.39
|
0.19
|
0.19
|
14:00
|
739.20
|
739.18
|
-0.02
|
0.02
|
|
15:00
|
738.50
|
738.72
|
0.22
|
0.22
|
15:00
|
733.60
|
733.63
|
0.03
|
0.03
|
|
16:00
|
693.70
|
693.63
|
-0.07
|
0.07
|
16:00
|
735.70
|
735.94
|
0.24
|
0.24
|
|
17:00
|
672.00
|
671.71
|
-0.29
|
0.29
|
17:00
|
732.20
|
732.08
|
-0.12
|
0.12
|
|
18:00
|
690.90
|
691.01
|
0.11
|
0.11
|
18:00
|
730.80
|
731.00
|
0.20
|
0.20
|
|
19:00
|
655.20
|
655.03
|
-0.17
|
0.17
|
19:00
|
721.70
|
721.43
|
-0.27
|
0.27
|
|
20:00
|
662.20
|
662.44
|
0.24
|
0.24
|
20:00
|
736.40
|
736.56
|
0.16
|
0.16
|
|
21:00
|
641.20
|
641.13
|
-0.07
|
0.07
|
21:00
|
716.80
|
716.80
|
0.00
|
0.00
|
|
22:00
|
693.70
|
693.79
|
0.09
|
0.09
|
22:00
|
690.20
|
690.24
|
0.04
|
0.04
|
|
23:00
|
648.90
|
649.01
|
0.11
|
0.11
|
23:00
|
695.10
|
694.87
|
-0.23
|
0.23
|
Measured data from United Water Toms River, Inc.,
supervisory control and data acquisition (SCADA) system output
Difference (gpm) = [measured flow (gpm)
- simulated flow (gpm)]; ABS Diff = absolute value of difference
![]() Holiday City Ground Level Storage Tank |
![]() Holly Plant Ground- Level Storage Tank |
![]() Indian Hill Elevated Storage Tank |
![]() North Dover Elevated Storage Tank |
![]() Parkway Well Field Ground-Level Storage Tank |