The following tables are contained in Appendix C and describe the monthly operation of the water-distribution system as simulated using the EPANET 2 (Rossman 2000) water-distribution system model:
Description of operations are taken from the EPANET 2 input data files for
the appropriate month and year and are described in the tables according to
the following basic format:
|
Month
|
Description of Operations
|
|
January
|
South Toms River elevated storage tank in service: Initial WL=16.0 feet
Indian Hill elevated storage tank in service: Initial WL=14.0 feet
Holly ground-level storage tank in service (closed in EPANET 2)
(note:Holly wells pump directly into system and represent Holly high-service
pump flows)
Holly high-service pump #1 on [0000 to 0600] and [1300 to 2400] at 900
gpm
Holly high-service pump #2 on [0600 to 1300] at 1,422 gpm)
Holly well #14 on [0600 to 1300] at 5 gpm
Holly well #16 on [0600 to 1300] at 240 gpm and [1300 to 2400] at 900
gpm
Holly well #18 on [0600 to 1300] at 616 gpm
Holly well #19 on [0600 to 1300] at 555 gpm
Holly well #21 on [0600 to 1300] at 5 gpm
Brookside well #15 on [0000 to 1800] and [2200 to 2400] at 692 gpm
South Toms River well #17 on [1800 to 2100] at 693 gpm
Indian Head well #20 on [1800 to 2200] at 499 gpm
|
|
February
(Minimum-Demand Month)
|
South Toms River elevated storage tank in service: Initial WL=18.0 feet
Indian Hill elevated storage tank in service: Initial WL=12.0 feet
Holly ground-level storage tank in service (closed in EPANET 2)
(note:Holly wells pump directly into system and represent Holly high-service
pump flows)
Holly high-service pump #1 on [0000 to 0600] and [1300 to 2400] at 900
gpm
Holly high-service pump #2 on [0600 to 1300] at 1,365 gpm)
(note:Holly well #14 out of service)
Holly well #16 on [0000 to 0600] at 900 gpm; [0600 to 1300] at 245 gpm;
[1300 to 2400] at 900 gpm
Holly well #18 on [0600 to 1300] at 807 gpm
Holly well #19 on [0600 to 1300] at 313 gpm
(note:Holly well #21 out of service)
Brookside well #15 on [0000 to 1100] and [2200 to 2400] at 685 gpm
South Toms River well #17 on [1700 to 2100] at 788 gpm
Indian Head well #20 on [0900 to 2200] at 490 gpm
Anchorage well #98 on [0700 to 0800] at 252 gpm
Silver Bay well #99 on [0800 to 0900] at 212 gpm
|
|
March
|
South Toms River elevated storage tank in service: Initial WL=18.0 feet
Indian Hill elevated storage tank in service: Initial WL=10.0 feet
Holly ground-level storage tank in service (closed in EPANET 2)
(note:Holly wells pump directly into system and represent Holly high-service
pump flows)
Holly high-service pump #1 on [0000 to 0600] and [1800 to 2400] at 900
gpm
Holly high-service pump #2 on [0600 to 1800] at 1,373 gpm)
Holly well #14 on [0600 to 1800] at 9 gpm
Holly well #16 on [0000 to 0600] at 900 gpm; [0600 to 1800] at 364 gpm;
[1800 to 2400] at 900 gpm
Holly well #18 on [0600 to 1800] at 928 gpm
Holly well #19 on [0600 to 1800] at 73 gpm
Brookside well #15 on [0000 to 1600] and [2200 to 2400] at 705 gpm
South Toms River well #17 on [1600 to 2100] at 745 gpm
Indian Head well #20 on [1700 to 2200] at 494 gpm
(note:Anchorage well #98 out of service)
(note:Silver Bay well #99 out of service)
|
|
April
|
South Toms River elevated storage tank in service: Initial WL=18.0 feet
Indian Hill elevated storage tank in service: Initial WL=8.0 feet
Holly ground-level storage tank in service (closed in EPANET 2)
(note:Holly wells pump directly into system and represent Holly high-service
pump flows)
Holly high-service pump #1 on [0000 to 2400] at 900 gpm
Holly high-service pump #2 on [0600 to 1800] at 1,254 gpm)
Holly well #14 on [0600 to 1800] at 125 gpm
Holly well #16 on [0000 to 0600] at 900 gpm; [0600 to 1800] at 493 gpm;
[1800 to 2400] at 900 gpm
Holly well #18 on [0600 to 1800] at 1,032 gpm
Holly well #19 on [0600 to 1800] at 430 gpm
Holly well #21 on [0600 to 1800] at 74 gpm
Brookside well #15 on [0000 to 1700] and [2200 to 2400] at 697 gpm
South Toms River well #17 on [1600 to 2100] at 684 gpm
Indian Head well #20 on [1100 to 2200] at 510 gpm
Anchorage well #98 on [0700 to 1000] at 426 gpm
Silver Bay well #99 on [1000 to 1400] at 380 gpm
|
|
May
|
South Toms River elevated storage tank in service: Initial WL=20.0 feet
Indian Hill elevated storage tank in service: Initial WL=15.0 feet
Holly ground-level storage tank in service (closed in EPANET 2)
(note:Holly wells pump directly into system and represent Holly high-service
pump flows)
Holly high-service pump #1 on [0000 to 2400] at 900 gpm
Holly high-service pump #2 on [0600 to 2100] at 1,237 gpm)
Holly well #14 on [0600 to 2100] at 114 gpm
Holly well #16 on [0000 to 0600] at 900 gpm; [0600 to 2100] at 583 gpm;
[2100 to 2400] at 900 gpm
Holly well #18 on [0600 to 2100] at 768 gpm
Holly well #19 on [0600 to 2100] at 646 gpm
Holly well #21 on [0600 to 2100] at 27 gpm
Brookside well #15 on [0000 to 1700] and [2200 to 2400] at 692 gpm
South Toms River well #17 on [0600 to 1200] and [2100 to 2200] at 783
gpm
Indian Head well #20 on [0800 to 1800] at 501 gpm
Anchorage well #98 on [0600 to 1200] at 379 gpm
Silver Bay well #99 on [1200 to 2100] at 394 gpm
|
|
June
|
South Toms River elevated storage tank in service: Initial WL=22.0 feet
Indian Hill elevated storage tank in service: Initial WL=9.0 feet
Holly ground-level storage tank in service (closed in EPANET 2)
(note:Holly wells pump directly into system and represent Holly high-service
pump flows)
Holly high-service pump #1 on [0000 to 2400] at 900 gpm
Holly high-service pump #2 on [0000 to 2400] at 1,409 gpm)
Parkway ground-level storage tank in service (closed in EPANET 2)
(note:Parkway wells pump directly into system and represent Parkway
high-service pump flows)
Parkway high-service pump #1 on [0800 to 0900] at 3195 gpm)
Holly well #14 on [0000 to 2400] at 249 gpm
Holly well #16 on [0000 to 2400] at 701 gpm
Holly well #18 on [0000 to 2400] at 561 gpm
Holly well #19 on [0000 to 2400] at 452 gpm
Holly well #21 on [0000 to 2400] at 345 gpm
Parkway well #22 on [0800 to 0900] at 1,304 gpm
Parkway well #23 on [0800 to 0900] at 651 gpm
Parkway well #27 on [0800 to 0900] at 1,239 gpm
Brookside well #15 on [0000 to 1500] and [1900 to 2400] at 710 gpm
South Toms River well #17 on [0700 to 1200] and [1500 to 2000] at 784
gpm
Indian Head well #20 on [0600 to 2100] at 488 gpm
Anchorage well #98 on [0600 to 2000] at 404 gpm
Silver Bay well #99 on [0500 to 2100] at 406 gpm
|
|
July
(Maximum-Demand Month)
|
South Toms River elevated storage tank in service: Initial WL=22.0 feet
Indian Hill elevated storage tank in service: Initial WL=10.0 feet
Holly ground-level storage tank in service (closed in EPANET 2)
(note:Holly wells pump directly into system and represent Holly high-service
pump flows)
Holly high-service pump #1 on [0000 to 2400] at 900 gpm
Holly high-service pump #2 on [0000 to 2400] at 1,445 gpm)
Parkway ground-level storage tank in service (closed in EPANET 2)
(note:Parkway wells pump directly into system and represent Parkway
high-service pump flows)
Parkway high-service pump #1 on [0700 to 1700] at 2,820 gpm)
Holly well #14 on [0000 to 2400] at 249 gpm
Holly well #16 on [0000 to 2400] at 699 gpm
Holly well #18 on [0000 to 2400] at 554 gpm
Holly well #19 on [0000 to 2400] at 490 gpm
Holly well #21 on [0000 to 2400] at 353 gpm
Parkway well #22 on [0700 to 1700] at 1,122 gpm
Parkway well #23 on [0700 to 1700] at 533 gpm
Parkway well #26 on [0700 to 1700] at 555 gpm
Parkway well #27 on [0700 to 1700] at 610 gpm
Brookside well #15 on [0000 to 2100] at 695 gpm
South Toms River well #17 on [0500 to 0700] and [1700 to 2200] at 729
gpm
Indian Head well #20 on [1000 to 2200] at 500 gpm
Anchorage well #98 on [0000 to 1000] and [1700 to 2400] at 403 gpm
Silver Bay well #99 on [0000 to 1000] and [1700 to 2400] at 399 gpm
|
|
August
|
South Toms River elevated storage tank in service: Initial WL=19.0 feet
Indian Hill elevated storage tank in service: Initial WL=17.0 feet
Holly ground-level storage tank in service (closed in EPANET 2)
(note:Holly wells pump directly into system and represent Holly high-service
pump flows)
Holly high-service pump #1 on [0000 to 2400] at 900 gpm
Holly high-service pump #2 on [0600 to 2300] at 1,351 gpm)
Parkway ground-level storage tank in service (closed in EPANET 2)
(note:Parkway wells pump directly into system and represent Parkway
high-service pump flows)
Parkway high-service pump #1 on [0800 to 1100] at 3,109 gpm)
Holly well #14 on [0600 to 2300] at 253 gpm
Holly well #16 on [0000 to 0600] at 900 gpm; [0600 to 2300] at 634 gpm;
[2300 to 2400] at 900 gpm
Holly well #18 on [0600 to 2300] at 625 gpm
Holly well #19 on [0600 to 2300] at 661 gpm
Holly well #21 on [0600 to 2300] at 78 gpm
Parkway well #22 on [0800 to 1100] at 917 gpm
Parkway well #23 on [0800 to 1100] at 444 gpm
Parkway well #26 on [0800 to 1100] at 954 gpm
Parkway well #27 on [0800 to 1100] at 794 gpm
Brookside well #15 on [0000 to 1900] and [2200 to 2400] at 692 gpm
South Toms River well #17 on [0600 to 0800] and [1900 to 2200] at 701
gpm
Indian Head well #20 on [1300 to 2200] at 508 gpm
Anchorage well #98 on [0000 to 1000] and [1800 to 2400] at 406 gpm
Silver Bay well #99 on [0000 to 1000] and [1800 to 2400] at 405 gpm
|
|
September
|
South Toms River elevated storage tank in service: Initial WL=15.0 feet
Indian Hill elevated storage tank in service: Initial WL=16.0 feet
Holly ground-level storage tank in service (closed in EPANET 2)
(note:Holly wells pump directly into system and represent Holly high-service
pump flows)
Holly high-service pump #1 on [0000 to 2400] at 900 gpm
Holly high-service pump #2 on [0600 to 1600] at 1,297 gpm)
Parkway ground-level storage tank in service (closed in EPANET 2)
(note:Parkway wells pump directly into system and represent Parkway
high-service pump flows)
Parkway high-service pump #1 on [0700 to 0900] at 2,719 gpm)
Holly well #14 on [0600 to 1600] at 201 gpm
Holly well #16 on [0000 to 0600] at 900 gpm; [0600 to 1600] at 467 gpm;
[1600 to 2400] at 900 gpm
Holly well #18 on [0600 to 1600] at 703 gpm
Holly well #19 on [0600 to 1600] at 785 gpm
Holly well #21 on [0600 to 1600] at 41 gpm
Parkway well #22 on [0700 to 0900] at 825 gpm
Parkway well #23 on [0700 to 0900] at 421 gpm
Parkway well #26 on [0700 to 0900] at 810 gpm
Parkway well #27 on [0700 to 0900] at 664 gpm
Brookside well #15 on [0000 to 1800] and [2200 to 2400] at 689 gpm
South Toms River well #17 on [2000 to 2200] at 883 gpm
Indian Head well #20 on [1200 to 2200] at 497 gpm
Anchorage well #98 on [0600 to 2200] at 403 gpm
Silver Bay well #99 on [0600 to 2200] at 398 gpm
|
|
October
(Average-Demand Month)
|
South Toms River elevated storage tank in service: Initial WL=14.0 feet
Indian Hill elevated storage tank in service: Initial WL=16.0 feet
Holly ground-level storage tank in service (closed in EPANET 2)
(note:Holly wells pump directly into system and represent Holly high-service
pump flows)
Holly high-service pump #1 on [0000 to 2400] at 900 gpm
Holly high-service pump #2 on [0600 to 1500] at 1,273 gpm)
(note:Parkway ground-level storage tank out of service)
(note:Holly well #14 out of service)
Holly well #16 on [0000 to 0600] at 900 gpm; [0600 to 1500] at 423 gpm;
[1500 to 2400] at 900 gpm
Holly well #18 on [0600 to 1500] at 898 gpm
Holly well #19 on [0600 to 1500] at 851 gpm
(note:Holly well #21 out of service)
(note:Parkway well #22 out of service)
(note:Parkway well #23 out of service)
(note:Parkway well #26 out of service)
(note:Parkway well #27 out of service)
Brookside well #15 on [0000 to 1700] and [2200 to 2400] at 701 gpm
South Toms River well #17 on [2000 to 2200] at 641 gpm
Indian Head well #20 on [1800 to 2200] at 449 gpm
Anchorage well #98 on [0600 to 2200] at 399 gpm
Silver Bay well #99 on [0600 to 2200] at 398 gpm
|
|
November
|
South Toms River elevated storage tank in service: Initial WL=15.0 feet
Indian Hill elevated storage tank in service: Initial WL=14.0 feet
Holly ground-level storage tank in service (closed in EPANET 2)
(note:Holly wells pump directly into system and represent Holly high-service
pump flows)
Holly high-service pump #1 on [0000 to 0600] and [1200 to 2400] at 900
gpm
Holly high-service pump #2 on [0600 to 1200] at 1,429 gpm)
Holly well #16 on [0000 to 0600] at 900 gpm; [0600 to 1200] at 106 gpm;
[1200 to 2400] at 900 gpm
Holly well #18 on [0600 to 1200] at 444 gpm
Holly well #19 on [0600 to 1200] at 878 gpm
Brookside well #15 on [0000 to 1800] and [2200 to 2400] at 709 gpm
South Toms River well #17 on [2100 to 2200] at 818 gpm
Indian Head well #20 on [1300 to 2200] at 478 gpm
Anchorage well #98 on [0600 to 1100] at 415 gpm
Silver Bay well #99 on [0600 to 1300] at 402 gpm
|
|
December
|
South Toms River elevated storage tank in service: Initial WL=13.0 feet
Indian Hill elevated storage tank in service: Initial WL=15.0 feet
Holly ground-level storage tank in service (closed in EPANET 2)
(note:Holly wells pump directly into system and represent Holly high-service
pump flows)
Holly high-service pump #1 on [0000 to 0600] and [2200 to 2400] at 900
gpm
Holly high-service pump #2 on [0600 to 2200] at 1,415 gpm)
Holly well #16 on [0000 to 0600] at 900 gpm; [0600 to 2200] at 593 gpm;
[2200 to 2400] at 900 gpm
Holly well #18 on [0600 to 2200] at 308 gpm
Holly well #19 on [0600 to 2200] at 514 gpm
Brookside well #15 on [0000 to 1900] and [2200 to 2400] at 712 gpm
(note:South Toms River well #17 out of service)
Indian Head well #20 on [0800 to 2200] at 489 gpm
(note:Anchorage well #98 out of service)
(note:Silver Bay well #99 out of service)
|
|
|
|
Month
|
Description of Operations
|
|
January
|
South Toms River elevated storage tank in service: Initial WL=17.0 feet
Indian Hill elevated storage tank in service: Initial WL=12.0 feet
Holly ground-level storage tank in service (closed in EPANET 2)
(note:Holly wells pump directly into system and represent Holly high-service
pump flows)
Holly high-service pump #1 on [0000 to 0600] and [1900 to 2400] at 900
gpm
Holly high-service pump #2 on [0600 to 1900] at 1,417 gpm)
Parkway ground-level storage tank in service (closed in EPANET 2)
(note:Parkway wells pump directly into system and represent Parkway
high-service pump flows)
Parkway high-service pump #1 on [0600 to 1300] and [1700 to 2300] at 2,837
gpm)
Holiday City ground-level storage tank in service: Initial WL=18.0
Holiday City booster pump off and bypass pipe open [0000 to 07:30]
Holiday City booster pump on (set at 0.87) and bypass pipe closed [07:30
to 12:30]
Holiday City booster pump off and bypass pipe closed [12:30 to 2200]
Holiday City booster pump off and bypass pipe open [2200 to 2400]
Holly well #16 on [0000 to 0600 at 900 gpm, [0600 to 1900] at 521 gpm,
[1900 to 2400] at 900 gpm
Holly well #18 on [0600 to 1900] at 896 gpm
(note:Holly well #19 out of service)
Parkway well #22 on [0600 to 1300] and [1700 to 2300] at 974 gpm
(note:Parkway well #23 out of service)
Parkway well #24 on [0600 to 1300] and [1700 to 2300] at 264 gpm
Parkway well #26 on [0600 to 1300] and [1700 to 2300] at 365 gpm
(note:Parkway well #27 out of service)
Parkway well #28 on [0600 to 1300] and [1700 to 2300] at 579 gpm
Parkway well #29 on [0600 to 1300] and [1700 to 2300] at 656 gpm
South Toms River well #17 on [0000 to 0400] and [2300 to 2400] at 788
gpm
Indian Head well #20 on [0000 to 2100] and [2200 to 2400] at 491gpm
|
|
February
(Minimum-Demand Month)
|
South Toms River elevated storage tank in service: Initial WL=17.0 feet
Indian Hill elevated storage tank in service: Initial WL=12.0 feet
Holly ground-level storage tank in service (closed in EPANET 2)
(note:Holly wells pump directly into system and represent Holly high-service
pump flows)
Holly high-service pump #1 on [0000 to 2400] at 896 gpm)
Parkway ground-level storage tank in service (closed in EPANET 2)
(note:Parkway wells pump directly into system and represent Parkway
high-service pump flows)
Parkway high-service pump #1 on [0600 to 1400] and [1700 to 2300] at 2,963
gpm)
Holiday City ground-level storage tank in service: Initial WL=18.0
Holiday City booster pump off and bypass pipe open [0000 to 07:30]
Holiday City booster pump on (set at 0.87) and bypass pipe closed [07:30
to 12:30]
Holiday City booster pump off and bypass pipe closed [12:30 to 2200]
Holiday City booster pump off and bypass pipe open [2200 to 2400]
Holly well #16 on [0000 to 2400] at 694 gpm
Holly well #18 on [0000 to 2400] at 202 gpm
Parkway well #22 on [0600 to 1400] and [1700 to 2300] at 1,009 gpm
Parkway well #24 on [0600 to 1400] and [1700 to 2300] at 29 gpm
Parkway well #26 on [0600 to 1400] and [1700 to 2300] at 733gpm
Parkway well #28 on [0600 to 1400] and [1700 to 2300] at 540 gpm
Parkway well #29 on [0600 to 1400] and [1700 to 2300] at 652 gpm
South Toms River well #17 on [0000 to 0400] and [2300 to 2400] at 815
gpm
Indian Head well #20 on [0000 to 2100] and [2200 to 2400] at 495 gpm
|
|
March
|
South Toms River elevated storage tank in service: Initial WL=17.0 feet
Indian Hill elevated storage tank in service: Initial WL=12.0 feet
Holly ground-level storage tank in service (closed in EPANET 2)
(note:Holly wells pump directly into system and represent Holly high-service
pump flows)
Holly high-service pump #1 on [0000 to 2400] at 832 gpm)
Parkway ground-level storage tank in service (closed in EPANET 2)
(note:Parkway wells pump directly into system and represent Parkway
high-service pump flows)
Parkway high-service pump #1 on [0600 to 1500] and [1700 to 2300] at 2,895
gpm)
Holiday City ground-level storage tank in service: Initial WL=18.0
Holiday City booster pump off and bypass pipe open [0000 to 07:30]
Holiday City booster pump on (set at 0.87) and bypass pipe closed [07:30
to 12:30]
Holiday City booster pump off and bypass pipe closed [12:30 to 2200]
Holiday City booster pump off and bypass pipe open [2200 to 2400]
Holly well #16 on [0000 to 2400] at 694 gpm
Holly well #18 on [0000 to 2400] at 138 gpm
Parkway well #22 on [0600 to 1500] and [1700 to 2300] at 861 gpm
Parkway well #23 on [0600 to 1500] and [1700 to 2300] at 3 gpm
Parkway well #24 on [0600 to 1500] and [1700 to 2300] at 512 gpm
Parkway well #26 on [0600 to 1500] and [1700 to 2300] at 626 gpm
Parkway well #27 on [0600 to 1500] and [1700 to 2300] at 330 gpm
Parkway well #28 on [0600 to 1500] and [1700 to 2300] at 209 gpm
Parkway well #29 on [0600 to 1500] and [1700 to 2300] at 353 gpm
South Toms River well #17 on [0000 to 0500] and [2300 to 2400] at 719
gpm
Indian Head well #20 on [0000 to 2100] and [2200 to 2400] at 491 gpm
|
|
April
|
South Toms River elevated storage tank in service: Initial WL=15.0 feet
Indian Hill elevated storage tank in service: Initial WL=8.0 feet
Holly ground-level storage tank in service (closed in EPANET 2)
(note:Holly wells pump directly into system and represent Holly high-service
pump flows)
Holly high-service pump #1 on [0000 to 0600] and [1900 to 2400] at 900
gpm
Holly high-service pump #2 on [0600 to 1900] at 1380 gpm)
Parkway ground-level storage tank in service (closed in EPANET 2)
(note:Parkway wells pump directly into system and represent Parkway
high-service pump flows)
Parkway high-service pump #1 on [0700 to 1900] at 3004 gpm)
Holiday City ground-level storage tank in service: Initial WL=18.0
Holiday City booster pump off and bypass pipe open [0000 to 07:30]
Holiday City booster pump on (set at 0.87) and bypass pipe closed [07:30
to 12:30]
Holiday City booster pump off and bypass pipe closed [12:30 to 2200]
Holiday City booster pump off and bypass pipe open [2200 to 2400]
Holly well #16 on [0000 to 0600] at 900 gpm, [0600 to 1900] at 521 gpm,
[1900 to 2400] at 900 gpm
Holly well #18 on [0600 to 1900] at 474 gpm
Holly well #19 on [0600 to 1900] at 386 gpm
Parkway well #22 on [0700 to 1900] at 606 gpm
(note:Parkway well #23 out of service)
Parkway well #24 on [0700 to 1900] at 529 gpm
Parkway well #26 on [0700 to 1900] at 431 gpm
Parkway well #27 on [0700 to 1900] at 460 gpm
Parkway well #28 on [0700 to 1900] at 515 gpm
Parkway well #29 on [0700 to 1900] at 463 gpm
Brookside well #15 on [0000 to 0800] and [2200 to 2400] at 713 gpm
South Toms River well #17 on [0000 to 0400] and [2200 to 2400] at 732
gpm
Indian Head well #20 on [0000 to 1300] and [2200 to 2400] at 500 gpm
|
|
May
|
South Toms River elevated storage tank in service: Initial WL=16.0 feet
Indian Hill elevated storage tank in service: Initial WL=9.0 feet
Holly ground-level storage tank in service (closed in EPANET 2)
(note:Holly wells pump directly into system and represent Holly high-service
pump flows)
Holly high-service pump #1 on [0000 to 0600] and [1700 to 2400] at 900
gpm
Holly high-service pump #2 on [0600 to 1700] at 1379 gpm)
Parkway ground-level storage tank in service (closed in EPANET 2)
(note:Parkway wells pump directly into system and represent Parkway
high-service pump flows)
Parkway high-service pump #1 on [0600 to 1900] at 2978 gpm)
Holiday City ground-level storage tank in service: Initial WL=19.0
Holiday City booster pump off and bypass pipe open [0000 to 06:30]
Holiday City booster pump on (set at 0.87) and bypass pipe closed [06:30
to 11:40]
Holiday City booster pump off and bypass pipe open [11:40 to 16:30]
Holiday City booster pump on (set at 0.87) and bypass pipe closed [16:30
to 20:30]
Holiday City booster pump off and bypass pipe open [20:30 to 2400]
Holly well #16 on [0000 to 0600] at 900 gpm, [0600 to 1700] at 452 gpm,
[1700 to 2400] at 900 gpm
Holly well #18 on [0600 to 1700] at 765 gpm
Holly well #19 on [0600 to 1700] at 162 gpm
Parkway well #22 on [0600 to 1900] at 542 gpm
Parkway well #23 on [0600 to 1900] at 150 gpm
Parkway well #24 on [0600 to 1900] at 394 gpm
Parkway well #25 on [0600 to 1900] at 113 gpm
Parkway well #26 on [0600 to 1900] at 439 gpm
Parkway well #27 on [0600 to 1900] at 438 gpm
Parkway well #28 on [0600 to 1900] at 443 gpm
Parkway well #29 on [0600 to 1900] at 459 gpm
Brookside well #15 on [0000 to 1200] and [2200 to 2400] at 706 gpm
South Toms River well #17 on [0000 to 0500] and [2200 to 2400] at 737
gpm
Indian Head well #20 on [0000 to 2400] at 505 gpm
Anchorage well #98 on [0000 to 0600] and [2200 to 2400] at 384 gpm
Silver Bay well #99 on [0000 to 0600] and [2200 to 2400] at 390 gpm
|
|
June
(Maximum-Demand Month)
|
South Toms River elevated storage tank in service: Initial WL=16.0 feet
Indian Hill elevated storage tank in service: Initial WL=9.0 feet
Holly ground-level storage tank in service (closed in EPANET 2)
(note:Holly wells pump directly into system and represent Holly high-service
pump flows)
Holly high-service pump #1 on [0000 to 2400] at 900 gpm
Holly high-service pump #2 on [0600 to 1700] at 1,267 gpm)
Parkway ground-level storage tank in service (closed in EPANET 2)
(note:Parkway wells pump directly into system and represent Parkway
high-service pump flows)
Parkway high-service pump #1 on [0400 to 0800] and [1100 to 1700] at 2,884
gpm
Parkway high-service pump #2 on [0800 to 1100] at 3985 gpm, [1700 to 2100]
at 3,957 gpm)
Holiday City ground-level storage tank in service: Initial WL=19.0
Holiday City booster pump off and bypass pipe open [0000 to 06:30]
Holiday City booster pump on (set at 0.87) and bypass pipe closed [06:30
to 11:40]
Holiday City booster pump off and bypass pipe open [11:40 to 16:30]
Holiday City booster pump on (set at 0.87) and bypass pipe closed [16:30
to 20:30]
Holiday City booster pump off and bypass pipe open [20:30 to 2400]
St. Catherine’s (Rt. 37) ground-level storage tank in service: Initial
WL=35.0
St. Catherine’s (Rt. 37) booster pump off and bypass pipe open [0000 to
0900]
St. Catherine’s (Rt. 37) booster pump on and bypass pipe closed [0900
to 12:30]
St. Catherine’s (Rt. 37) booster pump off and bypass pipe closed [12:30
to 17:30]
St. Catherine’s (Rt. 37) booster pump on and bypass pipe closed [17:30
to 21:15]
St. Catherine’s (Rt. 37) booster pump off and bypass pipe open [21:15
to 2400]
Holly well #16 on [0000 to 0600] at 900 gpm, [0600 to 1700] at 452 gpm,
[1700 to 2400] at 900 gpm
Holly well #18 on [0600 to 1700] at 1104 gpm
Holly well #19 on [0600 to 1700] at 496 gpm
Holly well #21 on [0600 to 1700] at 116 gpm
Parkway well #22 on [0400 to 0800] and [1100 to 1700] at 469 gpm, [0800
to 1100] and [1700 to 2100] at 669 gpm
Parkway well #23 on [0400 to 0800], [1100 to 1700] at 618 gpm
Parkway well #24 on [0400 to 0800] and [1100 to 1700] at 491 gpm, [0800
to 1100] at 613 gpm
Parkway well #25 on [0400 to 0800] and [1100 to 1700] at 106 gpm, [0800
to 1100] and [1700 to 2100] at 530 gpm
Parkway well #26 on [0400 to 0800] and [1100 to 1700] at 149 gpm, [0800
to 1100] and [1700 to 2100] at 745 gpm
Parkway well #27 on [0400 to 0800] and [1100 to 1700] at 410 gpm, [1700
to 2100] at 585 gpm
Parkway well #28 on [0400 to 0800] and [1100 to 1700] at 354 gpm, [0800
to 1100] and [1700 to 2100] at 708 gpm
Parkway well #29 on [0400 to 0800] and [1100 to 1700] at 288 gpm, [0800
to 1100] and [1700 to 2100] at 720 gpm
Brookside well #15 on [0000 to 1600] and [2200 to 2400] at 708 gpm
South Toms River well #17 on [0000 to 0600] and [2300 to 2400] at 774
gpm
Indian Head well #20 on [0000 to 2400] at 489 gpm
Anchorage well #98 on [0000 to 1100] and [1800 to 2400] at 394 gpm
Silver Bay well #99 on [0000 to 1000] and [1800 to 2400] at 409 gpm
|
|
July
|
South Toms River elevated storage tank in service: Initial WL=16.0 feet
Indian Hill elevated storage tank in service: Initial WL=10.0 feet
Holly ground-level storage tank in service (closed in EPANET 2)
(note:Holly wells pump directly into system and represent Holly high-service
pump flows)
Holly high-service pump #1 on [00:00 to 24:00] at 900 gpm
Holly high-service pump #2 on [06:00 to 18:00] at 1,274 gpm)
Parkway ground-level storage tank in service (closed in EPANET 2)
(note:Parkway wells pump directly into system and represent Parkway
high-service pump flows)
Parkway high-service pump #1 on [02:00 to 08:00] and [11:00 to 17:00]
at 2,986 gpm
Parkway high-service pump #2 on [08:00 to 11:00] and [17:00 to 21:00]
at 4,000 gpm)
Holiday City ground-level storage tank in service: Initial WL=18.0
Holiday City booster pump off and bypass pipe open [00:00 to 06:30]
Holiday City booster pump on (set at 0.87) and bypass pipe closed [06:30
to 11:40]
Holiday City booster pump off and bypass pipe open [11:40 to 16:30]
Holiday City booster pump on (set at 0.87) and bypass pipe closed [16:30
to 20:30]
Holiday City booster pump off and bypass pipe open [20:30 to 24:00]
St. Catherine’s (Rt. 37) ground-level storage tank in service: Initial
WL=35.0
St. Catherine’s (Rt. 37) booster pump off and bypass pipe open [00:00
to 09:00]
St. Catherine’s (Rt. 37) booster pump on and bypass pipe closed [09:00
to 12:30]
St. Catherine’s (Rt. 37) booster pump off and bypass pipe closed [12:30
to 17:30]
St. Catherine’s (Rt. 37) booster pump on and bypass pipe closed [17:30
to 21:15]
St. Catherine’s (Rt. 37) booster pump off and bypass pipe open [21:15
to 24:00]
Holly well #16 on [00:00 to 06:00] at 900 gpm, [06:00 to 18:00] at 489
gpm, [18:00 to 24:00] at 900 gpm
Holly well #18 on [06:00 to 18:00] at 998 gpm
Holly well #19 on [06:00 to 18:00] at 570 gpm
Holly well #21 on [06:00 to 18:00] at 118 gpm
Parkway well #22 on [02:00 to 08:00] and [11:00 to 17:00] at 428 gpm [08:00
to 11:00] and [17:00 to 21:00] at 641 gpm
Parkway well #23 on [02:00 to 08:00] and [11:00 to 17:00] at 324 gpm,
[08:00 to 11:00] and [17:00 to 21:00] at 354 gpm
Parkway well #24 on [02:00 to 08:00] and [11:00 to 17:00] at 560 gpm,
[08:00 to 11:00] at 611 gpm
Parkway well #25 on [02:00 to 08:00] and [11:00 to 17:00] at 253 gpm,
[08:00 to 11:00] and [17:00 to 21:00] at 505 gpm
Parkway well #26 on [02:00 to 08:00] and [11:00 to 17:00] at 320 gpm,
[08:00 to 11:00] and [17:00 to 21:00] at 512 gpm
Parkway well #27 on [02:00 to 08:00] and [11:00 to 17:00] at 356 gpm,
[17:00 to 21:00] at 609 gpm
Parkway well #28 on [02:00 to 08:00] and [11:00 to 17:00] at 398 gpm,
[08:00 to 11:00] and [17:00 to 21:00] at 682 gpm
Parkway well #29 on [02:00 to 08:00] and [11:00 to 17:00] at 348 gpm,
[08:00 to 11:00] and [17:00 to 21:00] at 696 gpm
Brookside well #15 on [00:00 to 19:00] and [22:00 to 24:00] at 685 gpm
South Toms River well #17 on [00:00 to 07:00] and [23:00 to 24:00] at
788 gpm
Indian Head well #20 on [00:00 to 24:00] at 490 gpm
Anchorage well #98 on [00:00 to 12:00] and [18:00 to 24:00] at 389 gpm
Silver Bay well #99 on [00:00 to 11:00] and [18:00 to 24:00] at 401 gpm
|
|
August
|
South Toms River elevated storage tank in service: Initial WL=17.0 feet
Indian Hill elevated storage tank in service: Initial WL=12.0 feet
Holly ground-level storage tank in service (closed in EPANET 2)
(note:Holly wells pump directly into system and represent Holly high-service
pump flows)
Holly high-service pump #1 on [0000 to 2400] at 900 gpm
Holly high-service pump #2 on [0600 to 1300] at 1,187 gpm)
Parkway ground-level storage tank in service (closed in EPANET 2)
(note:Parkway wells pump directly into system and represent Parkway
high-service pump flows)
Parkway high-service pump #1 on [0500 to 2000] at 2,967 gpm)
Holiday City ground-level storage tank in service: Initial WL=19.0
Holiday City booster pump off and bypass pipe open [0000 to 06:30]
Holiday City booster pump on (set at 0.87) and bypass pipe closed [06:30
to 11:40]
Holiday City booster pump off and bypass pipe open [11:40 to 16:30]
Holiday City booster pump on (set at 0.87) and bypass pipe closed [16:30
to 20:30]
Holiday City booster pump off and bypass pipe open [20:30 to 2400]
St. Catherine’s (Rt. 37) ground-level storage tank in service: Initial
WL=35.0
St. Catherine’s (Rt. 37) booster pump off and bypass pipe open [0000 to
0900]
St. Catherine’s (Rt. 37) booster pump on and bypass pipe closed [0900
to 12:30]
St. Catherine’s (Rt. 37) booster pump off and bypass pipe closed [12:30
to 17:30]
St. Catherine’s (Rt. 37) booster pump on and bypass pipe closed [17:30
to 21:15]
St. Catherine’s (Rt. 37) booster pump off and bypass pipe open [21:15
to 2400]
Holly well #16 on [0000 to 0600] at 900 gpm, [0600 to 1300] at 195 gpm,
[1300 to 2400] at 900 gpm
Holly well #18 on [0600 to 1300] at 1,608 gpm
Holly well #19 on [0600 to 1300] at 283 gpm
(note:Holly well #21 out of service)
Parkway well #22 on [0500 to 2000] at 366 gpm
Parkway well #23 on [0500 to 2000] at 308 gpm
Parkway well #24 on [0500 to 2000] at 409 gpm
Parkway well #25 on [0500 to 2000] at 346 gpm
Parkway well #26 on [0500 to 2000] at 333 gpm
Parkway well #27 on [0500 to 2000] at 319 gpm
Parkway well #28 on [0500 to 2000] at 459 gpm
Parkway well #29 on [0500 to 2000] at 427 gpm
Brookside well #15 on [0000 to 1900] and [2200 to 2400] at 685 gpm
South Toms River well #17 on [0000 to 0500] and [2300 to 2400] at 690
gpm
Indian Head well #20 on [0000 to 2400] at 503 gpm
Anchorage well #98 on [0000 to 1000] and [1800 to 2400] at 410 gpm
Silver Bay well #99 on [0000 to 1000] and [1800 to 2400] at 406 gpm
|
|
September
|
South Toms River elevated storage tank in service: Initial WL=16.0 feet
Indian Hill elevated storage tank in service: Initial WL=10.0 feet
Holly ground-level storage tank in service (closed in EPANET 2)
(note:Holly wells pump directly into system and represent Holly high-service
pump flows)
Holly high-service pump #1 on [0000 to 2400] at 900 gpm
Holly high-service pump #2 on [0600 to 1300] at 1,174 gpm)
Parkway ground-level storage tank in service (closed in EPANET 2)
(note:Parkway wells pump directly into system and represent Parkway
high-service pump flows)
Parkway high-service pump #1 on [0500 to 1900] at 2,883 gpm)
Holiday City ground-level storage tank in service: Initial WL=19.0
Holiday City booster pump off and bypass pipe open [0000 to 06:30]
Holiday City booster pump on (set at 0.87) and bypass pipe closed [06:30
to 11:40]
Holiday City booster pump off and bypass pipe open [11:40 to 16:30]
Holiday City booster pump on (set at 0.87) and bypass pipe closed [16:30
to 20:30]
Holiday City booster pump off and bypass pipe open [20:30 to 2400]
St. Catherine’s (Rt. 37) ground-level storage tank in service: Initial
WL=35.0
St. Catherine’s (Rt. 37) booster pump off and bypass pipe open [0000 to
0900]
St. Catherine’s (Rt. 37) booster pump on and bypass pipe closed [0900
to 12:30]
St. Catherine’s (Rt. 37) booster pump off and bypass pipe closed [12:30
to 17:30]
St. Catherine’s (Rt. 37) booster pump on and bypass pipe closed [17:30
to 21:15]
St. Catherine’s (Rt. 37) booster pump off and bypass pipe open [21:15
to 2400]
Holly well #16 on [0000 to 0600] at 900 gpm, [0600 to 1400] at 283 gpm,
[1400 to 2400] at 900 gpm
Holly well #18 on [0600 to 1400] at 1,705 gpm
Holly well #19 on [0600 to 1400] at 86 gpm
(note:Parkway well #22 out of service)
Parkway well #23 on [0500 to 1900] at 225 gpm
Parkway well #24 on [0500 to 1900] at 596 gpm
Parkway well #25 on [0500 to 1900] at 243 gpm
Parkway well #26 on [0500 to 1900] at 466 gpm
Parkway well #27 on [0500 to 1900] at 235 gpm
Parkway well #28 on [0500 to 1900] at 524 gpm
Parkway well #29 on [0500 to 1900] at 594 gpm
Brookside well #15 on [0000 to 1800] and [2200 to 2400] at 696 gpm
South Toms River well #17 on [0000 to 0400] and [2300 to 2400] at 810
gpm
Indian Head well #20 on [0000 to 2400] at 492 gpm
Anchorage well #98 on [0000 to 0700] and [2000 to 2400] at 389 gpm
Silver Bay well #99 on [0000 to 0700] and [2000 to 2400] at 387 gpm
|
|
October
|
South Toms River elevated storage tank in service: Initial WL=18.0 feet
Indian Hill elevated storage tank in service: Initial WL=15.0 feet
Holly ground-level storage tank in service (closed in EPANET 2)
(note:Holly wells pump directly into system and represent Holly high-service
pump flows)
Holly high-service pump #1 on [0000 to 0600] and [2200 to 2400] at 900
gpm
Holly high-service pump #2 on [0600 to 2200] at 1,478 gpm)
Parkway ground-level storage tank in service (closed in EPANET 2)
(note:Parkway wells pump directly into system and represent Parkway
high-service pump flows)
Parkway high-service pump #1 on [0600 to 1300] and [1800 to 2300] at 2,953
gpm)
Holiday City ground-level storage tank in service: Initial WL=18.0
Holiday City booster pump off and bypass pipe open [0000 to 07:30]
Holiday City booster pump on (set at 0.87) and bypass pipe closed [07:30
to 12:30]
Holiday City booster pump off and bypass pipe closed [12:30 to 2200]
Holiday City booster pump off and bypass pipe open [2200 to 2400]
(note:St. Catherine’s (Rt. 37) ground-level storage tank out of service)
Holly well #16 on [0000 to 0600] at 900 gpm, [0600 to 2200] at 592 gpm,
[2200 to 2400] at 900 gpm
Holly well #18 on [0600 to 2200] at 820 gpm
Holly well #19 on [0600 to 2200] at 67 gpm
(note:Parkway well #23 out of service)
Parkway well #24 on [0600 to 1300] and [1800 to 2300] at 793 gpm
(note:Parkway well #25 out of service)
Parkway well #26 on [0600 to 1300] and [1800 to 2300] at 607 gpm
(note:Parkway well #27 out of service)
Parkway well #28 on [0600 to 1300] and [1800 to 2300] at 788 gpm
Parkway well #29 on [0600 to 1300] and [1800 to 2300] at 765 gpm
Brookside well #15 on [0000 to 1900] and [2200 to 2400] at 698 gpm
South Toms River well #17 on [0000 to 0500] and [2300 to 2400] at 714
gpm
Indian Head well #20 on [0000 to 2400] at 487 gpm
(note:Anchorage well #98 out of service)
(note:Silver Bay well #99 out of service)
|
|
November
|
South Toms River elevated storage tank in service: Initial WL=15.0 feet
Indian Hill elevated storage tank in service: Initial WL=13.0 feet
Holly ground-level storage tank in service (closed in EPANET 2)
(note:Holly wells pump directly into system and represent Holly high-service
pump flows)
Holly high-service pump #1 on [0000 to 0600] and [2200 to 2400] at 900
gpm
Holly high-service pump #2 on [0600 to 2200] at 1,416 gpm)
Parkway ground-level storage tank in service (closed in EPANET 2)
(note:Parkway wells pump directly into system and represent Parkway
high-service pump flows)
Parkway high-service pump #1 on [0600 to 1300] and [1600 to 2300] at 2,905
gpm)
Holiday City ground-level storage tank in service: Initial WL=18.0
Holiday City booster pump off and bypass pipe open [0000 to 07:30]
Holiday City booster pump on (set at 0.87) and bypass pipe closed [07:30
to 12:30]
Holiday City booster pump off and bypass pipe closed [12:30 to 2200]
Holiday City booster pump off and bypass pipe open [2200 to 2400]
Holly well #16 on [0000 to 0600] at 900 gpm, [0600 to 2200] at 587 gpm,
[2200 to 2400] at 900 gpm
Holly well #18 on [0600 to 2200] at 812 gpm
Holly well #19 on [0600 to 2200] at 17 gpm
Parkway well #22 on [0600 to 1300] and [1600 to 2300] at 360 gpm
Parkway well #24 on [0600 to 1300] and [1600 to 2300] at 641 gpm
Parkway well #26 on [0600 to 1300] and [1600 to 2300] at 550 gpm
Parkway well #28 on [0600 to 1300] and [1600 to 2300] at 684 gpm
Parkway well #29 on [0600 to 1300] and [1600 to 2300] at 671 gpm
Brookside well #15 on [0000 to 0600] at 670 gpm
South Toms River well #17 on [0000 to 0200] at 871 gpm
Indian Head well #20 on [0000 to 1900] and [2200 to 2400] at 504 gpm
|
|
December
|
South Toms River elevated storage tank in service: Initial WL=19.0 feet
Indian Hill elevated storage tank in service: Initial WL=14.0 feet
Holly ground-level storage tank in service (closed in EPANET 2)
(note:Holly wells pump directly into system and represent Holly high-service
pump flows)
Holly high-service pump #1 on [0000 to 0600] and [1000 to 2400] at 900
gpm
Holly high-service pump #2 on [0600 to 1000] at 1,390 gpm)
Parkway ground-level storage tank in service (closed in EPANET 2)
(note:Parkway wells pump directly into system and represent Parkway
high-service pump flows)
Parkway high-service pump #1 on [0500 to 2200] at 2,951 gpm)
Holiday City ground-level storage tank in service: Initial WL=18.0
Holiday City booster pump off and bypass pipe open [0000 to 07:30]
Holiday City booster pump on (set at 0.87) and bypass pipe closed [07:30
to 12:30]
Holiday City booster pump off and bypass pipe closed [12:30 to 2200]
Holiday City booster pump off and bypass pipe open [2200 to 2400]
Holly well #16 on [0000 to 0600] at 900 gpm, [0600 to 1000] at 117 gpm,
[1200 to 2400] at 900 gpm
Holly well #18 on [0600 to 1000] at 1,263 gpm, [1000 to 1200] at 900 gpm
Holly well #19 on [0600 to 1000] at 10 gpm
Parkway well #22 on [0500 to 2200] at 304 gpm
Parkway well #24 on [0500 to 2200] at 721 gpm
Parkway well #26 on [0500 to 2200] at 431 gpm
Parkway well #28 on [0500 to 2200] at 762 gpm
Parkway well #29 on [0500 to 2200] at 733 gpm
(note:Brookside well #15 out of service)
South Toms River well #17 on [0000 to 0500] at 809 gpm
(note:Indian Head well #20 out of service)
|
|
|
|
Month
|
Description of Operations
|
|
January
|
South Toms River elevated storage tank in service: Initial WL=8.0 feet
South Toms River booster pump #1 and #2 off and bypass pipe open [0000
to 0700]
South Toms River booster pump #1 on, Booster Pump #2 off, bypass pipe
closed [0700 to 0900]
South Toms River booster pump #1 and #2 off and bypass pipe open [0900
to 1400]
South Toms River booster pump #1 off, Booster Pump #2 on, bypass pipe
closed [1400 to 1900]
South Toms River booster pump #1 and #2 off and bypass pipe open [1900
to 2400]
Indian Hill elevated storage tank in service: Initial WL=10.0 feet
Holly ground-level storage tank in service (closed in EPANET 2)
(note:Holly wells pump directly into system and represent Holly high-service
pump flows)
Holly high-service pump #1 on [0800 to 1300] at 893 gpm
Holly high-service pump #2 on [0000 to 0800] and [1300 to 2400] at 1394
gpm)
Parkway ground-level storage tank in service (closed in EPANET 2)
(note:Parkway wells pump directly into system and represent Parkway
high-service pump flows)
Parkway high-service pump #1 on [0800 to 1200] and [1600 to 2000] at 3,005
gpm)
Holiday City ground-level storage tank in service: Initial WL=24.0
Holiday City booster pump off and bypass pipe open [0000 to 06:45]
Holiday City booster pump on (set at 0.87) and bypass pipe closed [06:45
to 12:30]
Holiday City booster pump off and bypass pipe open [12:30 to 2400]
Holly well #21 on [0800 to 1300] at 425 gpm
Holly well #30 on [0800 to 1300] at 468 gpm, [0000 to 0800] and [1300
to 2400] at 1,394 gpm
Parkway well #22 on [0800 to 1200] and [1600 to 2000] at 680 gpm
Parkway well #23 on [0800 to 1200] and [1600 to 2000] at 317 gpm
Parkway well #24 on [0800 to 1200] and [1600 to 2000] at 1,506 gpm
Parkway well #29 on [0800 to 1200] and [1600 to 2000] at 502 gpm
Brookside well #15 on [0000 to 0200] and [0600 to 2400] at 701 gpm
(note:Indian Head well #20 out of service)
Route 70, well #31 on [0000 to 2100] and [2200 to 2400] at 702 gpm
South Toms River well #32 on [1200 to 1900] at 713 gpm
Berkeley well #33 on [0000 to 2400] at 1,169 gpm
Berkeley well #34 on [0900 to 1700] at 994 gpm
|
|
February
(Minimum-Demand Month)
|
South Toms River elevated storage tank in service: Initial WL=6.0 feet
South Toms River booster pump #1 and #2 off and bypass pipe open [0000
to 0700]
South Toms River booster pump #1 on, Booster Pump #2, bypass pipe closed
[0700 to 0900]
South Toms River booster pump #1 and #2 off, bypass pipe open [0900 to
1400]
South Toms River booster pump #1 off, Booster Pump #2 on, bypass pipe
closed [1400 to 2000]
South Toms River booster pump #1 and #2 off, bypass pipe open [2000 to
2400]
Indian Hill elevated storage tank in service: Initial WL=6.0 feet
Holly ground-level storage tank in service (closed in EPANET 2)
(note:Holly wells pump directly into system and represent Holly high-service
pump flows)
Holly high-service pump #1 on [0800 to 1200] at 900 gpm
Holly high-service pump #2 on [0800 to 1200] at 1,306 gpm,[0000 to 0800]
and [1200 to 2400] at 1,406 gpm)
Parkway ground-level storage tank in service (closed in EPANET 2)
(note:Parkway wells pump directly into system and represent Parkway
high-service pump flows)
Parkway high-service pump #1 on [0800 to 1100] and [1600 to 2000] at 2,897
gpm)
Holiday City ground-level storage tank in service: Initial WL=24.0
Holiday City booster pump off and bypass pipe open [0000 to 06:45]
Holiday City booster pump on (set at 0.87) and bypass pipe closed [06:45
to 12:30]
Holiday City booster pump off and bypass pipe open [12:30 to 2400]
(note:Holly well #21 out of service)
Holly well #30 on [0800 to 1200] at 2206 gpm, [0000 to 0800] and [1200
to 2400] at 1,406 gpm
Parkway well #22 on [0800 to 1100] and [1600 to 2000] at 1,080 gpm
(note:Parkway well #23 out of service)
Parkway well #24 on [0800 to 1100] and [1600 to 2000] at 1,817 gpm
(note:Parkway well #29 out of service)
Brookside well #15 on [0000 to 0300] at 597 gpm
Route 70, well #31 on [0000 to 2100] and [2200 to 2400] at 705 gpm
South Toms River well #32 on [1100 to 2000] at 677 gpm
Berkeley well #33 on [0000 to 2400] at 1,167 gpm
Berkeley well #34 on [0800 to 2000] at 1,003 gpm
|
|
March
|
South Toms River elevated storage tank in service: Initial WL=6.0 feet
South Toms River booster pump #1 and #2 off, bypass pipe open [0000 to
0700]
South Toms River booster pump #1 on, Booster Pump #2 off, bypass pipe
closed [0700 to 0900]
South Toms River booster pump #1 and #2 off, bypass pipe open [0900 to
1400]
South Toms River booster pump #1 off, Booster Pump #2 on, bypass pipe
closed [1400 to 2000]
South Toms River booster pump #1 and #2 off, bypass pipe open [2000 to
2400]
Indian Hill elevated storage tank in service: Initial WL=6.0 feet
Holly ground-level storage tank in service (closed in EPANET 2)
(note:Holly wells pump directly into system and represent Holly high-service
pump flows)
Holly high-service pump #1 on [0000 to 2400] at 951 gpm)
Parkway ground-level storage tank in service (closed in EPANET 2)
(note:Parkway wells pump directly into system and represent Parkway
high-service pump flows)
Parkway high-service pump #1 on [0800 to 1200] and [1600 to 2000] at 2,892
gpm)
Holiday City ground-level storage tank in service: Initial WL=24.0
Holiday City booster pump off and bypass pipe open [0000 to 06:45]
Holiday City booster pump on (set at 0.87) and bypass pipe closed [06:45
to 12:30]
Holiday City booster pump off and bypass pipe open [12:30 to 2400]
Holly well #30 on [0000 to 2400] at 951 gpm
Parkway well #22 on [0800 to 1200] and [1600 to 2000] at 1,293 gpm
Parkway well #24 on [0800 to 1200] and [1600 to 2000] at 1,599 gpm
Brookside well #15 on [0000 to 1000] and [2000 to 2400] at 708 gpm
Route 70, well #31 on [0000 to 2100] and [2200 to 2400] at 696 gpm
South Toms River well #32 on [1000 to 2000] at 670 gpm
Berkeley well #33 on [0000 to 2400] at 1,168 gpm
Berkeley well #34 on [0500 to 2200] at 1,005 gpm
|
|
April
|
South Toms River elevated storage tank in service: Initial WL=14.0 feet
South Toms River booster pump #1 and #2 off, bypass pipe open [0000 to
0700]
South Toms River booster pump #1 on, Booster Pump #2 off, bypass pipe
closed [0700 to 0900]
South Toms River booster pump #1 and #2 off, bypass pipe open [0900 to
1400]
South Toms River booster pump #1 off, Booster Pump #2 on, bypass pipe
closed [1400 to 1800]
South Toms River booster pump #1 and #2 off, bypass pipe open [1800 to
2400]
Indian Hill elevated storage tank in service: Initial WL=16.0 feet
Holly ground-level storage tank in service (closed in EPANET 2)
(note:Holly wells pump directly into system and represent Holly high-service
pump flows)
Holly high-service pump #1 on [0800 to 2200] at 915 gpm
Holly high-service pump #2 on [0000 to 800] and [2200 to 2400] at 1,400
gpm)
Parkway ground-level storage tank in service (closed in EPANET 2)
(note:Parkway wells pump directly into system and represent Parkway
high-service pump flows)
Parkway high-service pump #1 on [0800 to 1200] and [1500 to 2000] at 3,085
gpm)
Holiday City ground-level storage tank in service: Initial WL=24.0
Holiday City booster pump off and bypass pipe open [0000 to 06:45]
Holiday City booster pump on (set at 0.87) and bypass pipe closed [06:45
to 12:30]
Holiday City booster pump off and bypass pipe open [12:30 to 2400]
Holly well #30 on [0800 to 2200] at 915 gpm, [0000 to 800] and [2200 to
2400] at 1,400 gpm
Parkway well #22 on [0800 to 1200] and [1500 to 2000] at 1,573 gpm
Parkway well #24 on [0800 to 1200] and [1500 to 2000] at 1,511 gpm
Brookside well #15 on [0000 to 1500] and [2000 to 2400] at 698 gpm
Route 70, well #31 on [0000 to 2100] and [2200 to 2400] at 693 gpm
South Toms River well #32 on [1000 to 1800] at 681 gpm
Berkeley well #33 on [0000 to 2400] at 1,126 gpm
Berkeley well #34 on [0600 to 2200] at 1,021 gpm
|
|
May
|
South Toms River elevated storage tank in service: Initial WL=20.0 feet
South Toms River booster pump #1 and #2 off, bypass pipe open [00:00 to
07:00]
South Toms River booster pump #1 on, Booster Pump #2 off, bypass pipe
closed [07:00 to 09:00]
South Toms River booster pump #1 and #2 off, bypass pipe open [09:00 to
14:00]
South Toms River booster pump #1 off, Booster Pump #2 on, bypass pipe
closed [14:00 to 18:00]
South Toms River booster pump #1 and #2 off, bypass pipe open [18:00 to
24:00]
Indian Hill elevated storage tank in service: Initial WL=22.0 feet
Holly ground-level storage tank in service (closed in EPANET 2)
(note:Holly wells pump directly into system and represent Holly high-service
pump flows)
Holly high-service pump #2 on [0000 to 2400] at 1,352 gpm)
Parkway ground-level storage tank in service (closed in EPANET 2)
(note:Parkway wells pump directly into system and represent Parkway
high-service pump flows)
Parkway high-service pump #1 on [0700 to 1200] and [1500 to 2100] at 3,088
gpm)
Holiday City ground-level storage tank in service: Initial WL=24.0
Holiday City booster pump off and bypass pipe open [0000 to 06:45]
Holiday City booster pump on (set at 0.87) and bypass pipe closed [06:45
to 12:30]
Holiday City booster pump off and bypass pipe open [12:30 to 2400]
Holly well #21 on [0000 to 2400] at 34 gpm
Holly well #30 on [0000 to 2400] at 1,318 gpm
Parkway well #22 on [0700 to 1200] and [1500 to 2100] at 1,247 gpm
Parkway well #23 on [0700 to 1200] and [1500 to 2100] at 273 gpm
Parkway well #24 on [0700 to 1200] and [1500 to 2100] at 1,120 gpm
Parkway well #28 on [0700 to 1200] and [1500 to 2100] at 310 gpm
Parkway well #28 on [0700 to 1200] and [1500 to 2100] at 138 gpm
Brookside well #15 on [0000 to 1300] and [2000 to 2400] at 714 gpm
Route 70, well #31 on [0000 to 2100] and [2200 to 2400] at 698 gpm
South Toms River well #32 on [0900 to 1800] at 691 gpm
Berkeley well #33 on [0000 to 2400] at 1,158 gpm
Berkeley well #34 on [0500 to 2200] at 1,011 gpm
|
|
June
|
South Toms River elevated storage tank in service: Initial WL=17.0 feet
South Toms River booster pump #1 and #2 off, bypass pipe open [0000 to
0700]
South Toms River booster pump #1 on, Booster Pump #2 off, bypass pipe
closed [0700 to 1400]
South Toms River booster pump #1 off, Booster Pump #2 on, bypass pipe
closed [1400 to 1600]
South Toms River booster pump #1 and #2 off, bypass pipe open [1600 to
2000]
South Toms River booster pump #1 off, Booster Pump #2 on, bypass pipe
closed [2000 to 21:30]
South Toms River booster pump #1 and #2 off, bypass pipe open [21:30 to
2400]
Indian Hill elevated storage tank in service: Initial WL=12.0 feet
Holly ground-level storage tank in service (closed in EPANET 2)
(note:Holly wells pump directly into system and represent Holly high-service
pump flows)
Holly high-service pump #1 on [0600 to 0900], [1200 to 1800], [2100 to
2200] at 900 gpm
Windsor ground-level storage tank in service: Initial WL=24.0
Windsor high-service pump #1 and #2 off, bypass pipe open [0000 to 08:30]
Windsor high-service pump #1 on, Booster Pump #2 off, bypass pipe closed
[08:30 to 1500]
Windsor high-service pump #1 and #2 off, bypass pipe open [1500 to 2400]
Holly well #21 on [0000 to 0600] and [2200 to 2400] at 1,160 gpm
Holly well #30 on [0000 to 0600] and [2200 to 2400] at 236 gpm, [0600
to 0900], [1200 to 1800] and [2100 to 2200] at 2,194 gpm, [0900 to 1200]
and [1800 to 2100] at 2,794 gpm
Parkway well #22 on [0500 to 0700], [0700 to 1000] at 4000 gpm, [1200
to 1700] at 263 gpm
Parkway well #23 on [0500 to 0700] and [1200 to 1700] at 985 gpm
Parkway well #24 on [0500 to 0700] and [1200 to 1700] at 173 gpm, 1000
to 1200] and [1700 to 1800] at 4,000 gpm
Parkway well #28 on [0500 to 0700] and [1200 to 1700] at 174 gpm, 1800
to 2100] at 4,000 gpm
Parkway well #29 on [0500 to 0700] and [1200 to 1700] at 1,489 gpm
Brookside well #15 on [0000 to 0900] and [1500 to 2400] at 715 gpm
Indian Head #20 on [0000 to 0800] at 515 gpm
Route 70, well #31 on [0000 to 2100] and [2200 to 2400] at 695 gpm
South Toms River well #32 on [0400 to 2200] at 703 gpm
Berkeley well #33 on [0000 to 2400] at 1,154 gpm
Berkeley well #34 on [0000 to 2400] at 1,106 gpm
|
|
July
(Maximum-Demand Month)
|
South Toms River elevated storage tank in service: Initial WL=20.0 feet
South Toms River booster pump #1 and #2 off, bypass pipe open [0000 to
0400]
South Toms River booster pump #1 on, Booster Pump #2 off, bypass pipe
closed [0400 to 1400]
South Toms River booster pump #1 off, Booster Pump #2 on, bypass pipe
closed [1400 to 1900]
South Toms River booster pump #1 and #2 off, bypass pipe open [1900 to
2400]
Indian Hill elevated storage tank in service: Initial WL=13.0 feet
Holly ground-level storage tank in service (closed in EPANET 2)
(note:Holly wells pump directly into system and represent Holly high-service
pump flows)
Holly high-service pump #1 on [0500 to 0800] and [1300 to 1700] at 900
gpm
Holly high-service pump #2 on [0500 to 0800] and [1300 to 1700] at 1,300
gpm, [0000 to 0500] and [2200 to 2400] at 1,628 gpm
Holly high-service pump #3 on [0800 to 1300] and [1700 to 2200] at 3,000
gpm)
Parkway ground-level storage tank in service (closed in EPANET 2)
(note:Parkway wells pump directly into system and represent Parkway
high-service pump flows)
Parkway high-service pump #1 on [0400 to 0700] and [1200 to 1700] at 2,936
gpm
Parkway high-service pump #2 on [0700 to 1200] and [1700 to 2100] at 4,000
gpm)
Holiday City ground-level storage tank in service: Initial WL=20.0
Holiday City booster pump off and bypass pipe open [0000 to 06:30]
Holiday City booster pump on (set at 0.87) and bypass pipe closed [06:30
to 11:30]
Holiday City booster pump off and bypass pipe open [11:30 to 16:30]
Holiday City booster pump on (set at 0.87) and bypass pipe closed [16:30
to 20:30]
Holiday City booster pump off and bypass pipe open [20:30 to 2400]
St. Catherine’s (Rt. 37) ground-level storage tank in service: Initial
WL=40.0
St. Catherine’s (Rt. 37) booster pump off and bypass pipe open [0000 to
09:30]
St. Catherine’s (Rt. 37) booster pump on and bypass pipe closed [09:30
to 14:45]
St. Catherine’s (Rt. 37) booster pump off and bypass pipe closed [14:45
to 2000]
St. Catherine’s (Rt. 37) booster pump off and bypass pipe open [2000 to
2400]
Windsor ground-level storage tank in service: Initial WL=24.0
Windsor high-service pump #1 and #2 off, bypass pipe open [0000 to 08:30]
Windsor high-service pump #1 on, Booster Pump #2 off, bypass pipe closed
[08:30 to 1400]
Windsor high-service pump #1 and #2 off, bypass pipe open [1400 to 2400]
Holly well #21 on [0000 to 0500] and [0500 to 0600] at 2,200 gpm, [2200
to 2400] at 1,431 gpm
Holly well #30 on [0000 to 0500] and [2200 to 2400] at 197 gpm, [0600
to 0800] and [1300 to 1700] at 2200 gpm, [0800 to 1300] and [1700 to 2200]
at 3,000 gpm
Parkway well #22 on [0400 to 0700] at 457 gpm, [0700 to 0900] at 4000
gpm, [1200 to 1700] at 457 gpm
Parkway well #23 on [0400 to 0700] and [1200 to 1700] at 738 gpm
Parkway well #24 on [0400 to 0700] at 372 gpm, [0900 to 1100] at 4000
gpm, [1200 to 1700] at 372 gpm
Parkway well #26 on [0400 to 0700] and [1200 to 1700] at 242 gpm, [1100
to 1200] and [1700 to 1800] at 4,000 gpm
Parkway well #28 on [0400 to 0700] and [1200 to 1700] at 431 gpm, [1800
to 2000] at 4,000 gpm
Parkway well #29 on [0400 to 0700] and [1200 to 1700] at 696 gpm, [2000
to 2100] at 4,000 gpm
Brookside well #15 on [0000 to 0900] and [1600 to 2400] at 707 gpm
Indian Head #20 on [0000 to 1800] and [2200 to 2400] at 488 gpm
Route 70, well #31 on [0000 to 2000] and [2200 to 2400] at 686 gpm
South Toms River well #32 on [0500 to 2200] at 706 gpm
South Toms River well #38 on [0400 to 1200] at 665 gpm
Berkeley well #33 on [0000 to 2400] at 1,134 gpm
Berkeley well #34 on [0000 to 2100] and [2200 to 2400] at 998 gpm
Berkeley well #35 on [0500 to 2200] at 708 gpm
|
|
August
|
South Toms River elevated storage tank in service: Initial WL=10.0 feet
South Toms River booster pump #1 and #2 off, bypass pipe open [0000 to
0500]
South Toms River booster pump #1 on, Booster Pump #2 off, bypass pipe
closed [0500 to 1400]
South Toms River booster pump #1 off, Booster Pump #2 on, bypass pipe
closed [1400 to 1600]
South Toms River booster pump #1 and #2 off, bypass pipe open [1600 to
1900]
South Toms River booster pump #1 off, Booster Pump #2 on, bypass pipe
closed [1900 to 21:30]
South Toms River booster pump #1 and #2 off, bypass pipe open [21:30 to
2400]
Indian Hill elevated storage tank in service: Initial WL=11.0 feet
Holly ground-level storage tank in service (closed in EPANET 2)
(note:Holly wells pump directly into system and represent Holly high-service
pump flows)
Holly high-service pump #1 on [0600 to 0800], [1200 to 1700], [2100 to
2200] at 900 gpm
Holly high-service pump #2 on [0600 to 0800], [1200 to 1700], [2100 to
2200] at 1,300 gpm, [0000 to 0600] and [2200 to 2400] at 1,400 gpm
Holly high-service pump #3 on [0800 to 1200] and [1700 to 2100] at 2,852
gpm)
Parkway ground-level storage tank in service (closed in EPANET 2)
(note:Parkway wells pump directly into system and represent Parkway
high-service pump flows)
Parkway high-service pump #1 on [0400 to 0800] and [1200 to 1800] at 2,887
gpm
Parkway high-service pump #2 on [0800 to 1200] and [1800 to 2100] at 4,000
gpm)
Holiday City ground-level storage tank in service: Initial WL=21.0
Holiday City booster pump off and bypass pipe open [0000 to 06:30]
Holiday City booster pump on (set at 0.87) and bypass pipe closed [06:30
to 11:30]
Holiday City booster pump off and bypass pipe open [11:30 to 16:30]
Holiday City booster pump on (set at 0.87) and bypass pipe closed [16:30
to 20:30]
Holiday City booster pump off and bypass pipe open [20:30 to 2400]
St. Catherine’s (Rt. 37) ground-level storage tank in service: Initial
WL=40.0
St. Catherine’s (Rt. 37) booster pump off and bypass pipe open [0000 to
09:30]
St. Catherine’s (Rt. 37) booster pump on and bypass pipe closed [09:30
to 14:45]
St. Catherine’s (Rt. 37) booster pump off and bypass pipe closed [14:45
to 2000]
St. Catherine’s (Rt. 37) booster pump off and bypass pipe open [2000 to
2400]
Windsor ground-level storage tank in service: Initial WL=24.0
Windsor high-service pump #1 and #2 off, bypass pipe open [0000 to 08:30]
Windsor high-service pump #1 on, Booster Pump #2 off, bypass pipe closed
[08:30 to 1500]
Windsor high-service pump #1 and #2 off, bypass pipe open [1500 to 2400]
Holly well #21 on [0800 to 1200] and [1700 to 2100] at 959 gpm
Holly well #30 on [0000 to 0600] and [2200 to 2400] at 1,400 gpm, [0800
to 1200] at 1,893 gpm,
[1700 to 2100] at 1,893 gpm, [0600 to 0800], [1200 to 1700], [2100 to
2200] at 2,200 gpm
Parkway well #22 on [0400 to 0800] at 726 gpm, [0800 to 0900] at 4,000
gpm, [1200 to 1800] at 726 gpm
Parkway well #23 on [0400 to 0800] and [1200 to 1800] at 565 gpm
Parkway well #24 on [0400 to 0800] at 211 gpm, [0900 to 1100] at 4,000
gpm, [1200 to 1800] at 211 gpm
Parkway well #26 on [0400 to 0800] at 576 gpm, [1100 to 1200] at 4,000
gpm, [1200 to 1800] at 576 gpm
Parkway well #28 on [0400 to 0800] and [1200 to 1800] at 288 gpm, [1800
to 2000] at 4,000 gpm
Parkway well #29 on [0400 to 0800] and [1200 to 1800] at 521 gpm, [2000
to 2100] at 4,000 gpm
Brookside well #15 on [0000 to 0800] and [1500 to 2400] at 716 gpm
Indian Head #20 on [0000 to 0800] and [1100 to 2400] at 596 gpm
Route 70, well #31 on [0000 to 2000] and [2200 to 2400] at 699 gpm
South Toms River well #32 on [0500 to 1900] at 674 gpm
South Toms River well #38 on [0500 to 1100] at 674 gpm
Berkeley well #33 on [0000 to 2000] and [2200 to 2400] at 988 gpm
Berkeley well #34 on [0000 to 1100] and [1700 to 2400] at 983 gpm
Berkeley well #35 on [0600 to 1900] at 720 gpm
|
|
September
|
South Toms River elevated storage tank in service: Initial WL=12.0 feet
South Toms River booster pump #1 and #2, bypass pipe open [0000 to 1400]
South Toms River booster pump #1 off, Booster Pump #2 on, bypass pipe
closed [1400 to 2000]
South Toms River booster pump #1 and #2 off, bypass pipe open [2000 to
2400]
Indian Hill elevated storage tank in service: Initial WL=17.0 feet
Holly ground-level storage tank in service (closed in EPANET 2)
(note:Holly wells pump directly into system and represent Holly high-service
pump flows
Holly high-service pump #1 on [0400 to 2300] at 909 gpm
Holly high-service pump #2 on [0000 to 0400] and [2300 to 2400] at 1,400
gpm)
Parkway ground-level storage tank in service (closed in EPANET 2)
(note:Parkway wells pump directly into system and represent Parkway
high-service pump flows
Parkway high-service pump #1 on [0400 to 0800] and [1200 to 1700] at 2,910
gpm
Parkway high-service pump #2 on [0800 to 1200] and [1700 to 2100] at 4,000
gpm)
Holiday City ground-level storage tank in service: Initial WL=24.0
Holiday City booster pump off and bypass pipe open [0000 to 06:45]
Holiday City booster pump on (set at 0.87) and bypass pipe closed [06:45
to 12:30]
Holiday City booster pump off and bypass pipe open [12:30 to 2400]
(note:St. Catherine’s (Rt. 37) ground-level storage tank out of service)
(note:Windsor ground-level storage tank out of service)
(note:Holly well #21 out of service)
Holly well #30 on [0000 to 0400] at 1,400 gpm, [0400 to 2300] at 909 gpm,
[2300 to 2400] at 1,400 gpm
Parkway well #22 on [0400 to 0800] a 272 gpm, [0800 to 1000] at 4,000
gpm, [1200 to 1700] at 272 gpm
Parkway well #23 on [0400 to 0800] and [1200 to 1700] at 603 gpm
Parkway well #24 on [0400 to 0800] at 199 gpm, [1000 to 1200] at 4,000
gpm, [1200 to 1700] at 199 gpm
Parkway well #26 on [0400 to 0800] and [1200 to 1700] at 155 gpm, [1700
to 1900] at 4,000 gpm
Parkway well #28 on [0400 to 0800] and [1200 to 1700] at 255 gpm, [1900
to 2100] at 4,000 gpm
Parkway well #29 on [0400 to 0800] and [1200 to 1700] at 1,426 gpm
Brookside well #15 on [0000 to 0700] and [2200 to 2400] at 694 gpm
Indian Head #20 on [0000 to 1900] and [2200 to 2400] at 495 gpm
Route 70, well #31 on [0000 to 1900] and [2200 to 2400] at 703 gpm
South Toms River well #32 on [1200 to 2000] at 710 gpm
South Toms River well #38 on [0600 to 0700] at 60 gpm
Berkeley well #33 on [0000 to 2000] and [2200 to 2400] at 1,010 gpm
Berkeley well #34 on [0500 to 2200] at 989 gpm
Berkeley well #35 on [0700 to 2100] at 694 gpm
|
|
October
(Average-Demand Month)
|
South Toms River elevated storage tank in service: Initial WL=8.0 feet
South Toms River booster pump #1 and #2 off, bypass pipe open [0000 to
1400]
South Toms River booster pump #1 off, Booster Pump #2 on, bypass pipe
closed [1400 to 2000]
South Toms River booster pump #1 and #2 off, bypass pipe open [2000 to
2400]
Indian Hill elevated storage tank in service: Initial WL=11.0 feet
Holly ground-level storage tank in service (closed in EPANET 2)
(note:Holly wells pump directly into system and represent Holly high-service
pump flows)
Holly high-service pump #1 on [0000 to 2400] at 936 gpm)
Parkway ground-level storage tank in service (closed in EPANET 2)
(note:Parkway wells pump directly into system and represent Parkway
high-service pump flows)
Parkway high-service pump #1 on [0400 to 0700] and [1200 to 1700] at 2,925
gpm
Parkway high-service pump #2 on [0700 to 1200] and [1700 to 2100] at 4,000
gpm)
Holiday City ground-level storage tank in service: Initial WL=24.0
Holiday City booster pump off and bypass pipe open [0000 to 06:45]
Holiday City booster pump on (set at 0.87) and bypass pipe closed [06:45
to 12:30]
Holiday City booster pump off and bypass pipe open [12:30 to 2400]
Holly well #30 on [0000 to 2400] at 936 gpm
Parkway well #22 on [0400 to 0700] at 452 gpm, [0700 to 0900] at 4,000
gpm, [1200 to 1700] at 452 gpm
Parkway well #23 on [0400 to 0700] and [1200 to 1700] at 766 gpm
Parkway well #24 on [0400 to 0700] at 339 gpm, [0900 to 1100] at 4,000
gpm, [1200 to 1700] at 339 gpm
Parkway well #26 on [0400 to 0700] and [1200 to 1700] at 287 gpm, [1100
to 1200] and [1700 to 1800] at 4,000 gpm
Parkway well #28 on [0400 to 0700] and [1200 to 1700] at 398 gpm, [1800
to 2000] at 4,000 gpm
Parkway well #28 on [0400 to 0700] and [1200 to 1700] at 682 gpm, [2000
to 2100] at 4,000 gpm
Indian Head #20 on [0000 to 1900] and [2200 to 2400] at 493 gpm
Route 70, well #31 on [0000 to 2000] and [2200 to 2400] at 697 gpm
South Toms River well #32 on [1300 to 2000] at 698 gpm
(note:South Toms River well #38 out of service)
Berkeley well #33 on [0000 to 2400] at 988 gpm
Berkeley well #34 on [0700 to 2100] at 975 gpm
Berkeley well #35 on [0600 to 0900] at 623 gpm
|
|
November
|
South Toms River elevated storage tank in service: Initial WL=8.0 feet
South Toms River booster pump #1 and #2 off, bypass pipe open [00:00 to
07:00]
South Toms River booster pump #1 on, Booster Pump #2 off, bypass pipe
closed [07:00 to 09:00]
South Toms River booster pump #1 and #2 off, bypass pipe open [09:00 to
14:00]
South Toms River booster pump #1 off, Booster Pump #2 on, bypass pipe
closed [14:00 to 20:00]
South Toms River booster pump #1 & #2 off and bypass pipe open [20:00
to 24:00]
Indian Hill elevated storage tank in service: Initial WL=10.0 feet
Holly ground-level storage tank in service (closed in EPANET 2)
(note:Holly wells pump directly into system and represent Holly high-service
pump flows)
Holly high-service pump #1 on [00:00 to 24:00] at 847 gpm)
Parkway ground-level storage tank in service (closed in EPANET 2)
(note:Parkway wells pump directly into system and represent Parkway
high-service pump flows)
Parkway high-service pump #1 on [04:00 to 07:00] and [12:00 to 17:00]
at 2,925 gpm
Parkway high-service pump #2 on [07:00 to 12:00] and [17:00 to 21:00]
at 4,000 gpm)
Holiday City ground-level storage tank in service: Initial WL=24.0
Holiday City booster pump off and bypass pipe open [00:00 to 06:45]
Holiday City booster pump on (set at 0.87) and bypass pipe closed [06:45
to 12:30]
Holiday City booster pump off and bypass pipe open [12:30 to 24:00]
Holly well #21 on [00:00 to 24:00] at 61 gpm
Holly well #30 on [00:00 to 24:00] at 785 gpm
Parkway well #22 on [08:00 to 12:00] and [15:00 to 20:00] at 672 gpm
Parkway well #23 on [08:00 to 12:00] and [15:00 to 20:00] at 136 gpm
Parkway well #24 on [0800 to 1200] and [1500 to 2000] at 637 gpm
Parkway well #26 on [0800 to 1200] and [1500 to 2000] at 600 gpm
Parkway well #28 on [0800 to 1200] and [1500 to 2000] at 476 gpm
Parkway well #29 on [0800 to 1200] and [1500 to 2000] at 566 gpm
Brookside well #15 on [0000 to 0400] and [1900 to 2400] at 713 gpm
Indian Head #20 on [0000 to 1900] and [2200 to 2400] at 493 gpm
Route 70, well #31 on [0000 to 2100] and [2200 to 2400] at 686 gpm
South Toms River well #32 on [1100 to 2000] at 683 gpm
(note:South Toms River well #38 out of service)
Berkeley well #33 on [0000 to 2400] at 996 gpm
Berkeley well #34 on [0700 to 2200] at 992 gpm
Berkeley well #35 on [0700 to 1500] at 676 gpm
|
|
December
|
South Toms River elevated storage tank in service: Initial WL=12.0 feet
South Toms River booster pump #1 and #2 off, bypass pipe open [0000 to
1000]
South Toms River booster pump #1 on, Booster Pump #2 off, bypass pipe
closed [1000 to 1400]
South Toms River booster pump #1 and #2 off, bypass pipe open [1400 to
2400]
Indian Hill elevated storage tank in service: Initial WL=16.0 feet
Holly ground-level storage tank in service (closed in EPANET 2)
(note:Holly wells pump directly into system and represent Holly high-service
pump flows)
Parkway ground-level storage tank in service (closed in EPANET 2)
(note:Parkway wells pump directly into system and represent Parkway
high-service pump flows)
Parkway high-service pump #1 on [0500 to 0900], [1200 to 1800], [2100
to 2300] at 2,977 gpm
Parkway high-service pump #2 on [0900 to 1200] and [1800 to 2100] at 4,000
gpm)
Holiday City ground-level storage tank in service: Initial WL=24.0
oliday City booster pump off and bypass pipe open [0000 to 06:45]
Holiday City booster pump on (set at 0.87) and bypass pipe closed [06:45
to 12:30]
Holiday City booster pump off and bypass pipe open [12:30 to 2400]
(note:Holly well #21 out of service)
(note:Holly well #30 out of service)
Parkway well #22 on [0500 to 0900], [1200 to 1800], [2100 to 2300] at
83 gpm, [0900 to 1200] at 4,000 gpm
(note:Parkway well #23 out of service)
Parkway well #24 on [0500 to 0900], [1200 to 1800] and [2100 to 2300]
at 34 gpm; [1800 to 2100] at 4,000 gpm
Parkway well #26 on [0500 to 0900], [1200 to 1800], [2100 to 2300] at
953 gpm
Parkway well #28 on [0500 to 0900], [1200 to 1800], [2100 to 2300] at
1,050 gpm
Parkway well #29 on [0500 to 0900], [1200 to 1800], [2100 to 2300] at
856 gpm
(note: Brookside well #15 out of service)
Indian Head well #20 on [0000 to 0600] and [1900 to 2400] at 490 gpm
Route 70, well #31 on [0000 to 1000] and [1200 to 2400] at 703 gpm
South Toms River well #32 on [0700 to 1400] at 691 gpm
South Toms River well #38 on [0600 to 0700] at 676 gpm
Berkeley well #33 on [0000 to 2400] at 989 gpm
Berkeley well #34 on [0600 to 1900] at 1,002 gpm
Berkeley well #35 on [1000 to 1900] at 699 gpm
|
|
Month
|
Description of Operations
|
|
January
|
Indian Hill elevated storage tank in service: Initial WL=18.0 feet
Parkway ground-level storage tank in service (closed in EPANET 2)
(note:Parkway wells pump directly into system and represent Parkway
high-service pump flows)
Parkway high-service pump #1 on [0500 to 2200] at 3037 gpm)
Holiday City ground-level storage tank in service: Initial WL=17.0 feet
Holiday City booster pump off and bypass pipe open from [0000 to 0600]
Holiday City booster pump on (set at 0.87) and bypass pipe closed from
[0600 to 1100]
Holiday City booster pump off and bypass pipe closed from [1100 to 2300]
Holiday City booster pump off and bypass pipe open from [2300 to 2400]
North Dover elevated storage tank in service: Initial WL=26.0 feet
Parkway well #22 on [0500 to 2200] at 624 gpm
Parkway well #24 on [0500 to 2200] at 394 gpm
Parkway well #26 on [0500 to 2200] at 179 gpm
Parkway well #28 on [0500 to 2200] at 602 gpm
Parkway well #29 on [0500 to 2200] at 126 gpm
Parkway well #42 on [0500 to 2200] at 1,112 gpm
Indian Head well #20 on [0000 to 1100] and [1700 to 2400] at 451 gpm
Route 70, well #31 on [0000 to 1300] and [1500 to 2400] at 660 gpm
South Toms River well #32 on [0000 to 2400] at 513 gpm
Berkeley well #33 on [0000 to 1300] and [1600 to 2400] at 903 gpm
Berkeley well #34 on [0200 to 2300] at 878 gpm
Berkeley well #35 on [0200 to 2300] at 615 gpm
|
|
February
(Minimum-Demand Month)
|
Indian Hill elevated storage tank in service: Initial WL=18.0 feet
Parkway ground-level storage tank in service (closed in EPANET 2)
(note:Parkway wells pump directly into system and represent Parkway
high-service pump flows)
Parkway high-service pump #1 on [0500 to 2300] at 3004 gpm)
Holiday City ground-level storage tank in service: Initial WL=17.0 feet
Holiday City booster pump off and bypass pipe open from [0000 to 0600]
Holiday City booster pump on (set at 0.87) and bypass pipe closed from
[0600 to 1100]
Holiday City booster pump off and bypass pipe closed from [1100 to 2300]
Holiday City booster pump off and bypass pipe open from [2300 to 2400]
North Dover elevated storage tank in service: Initial WL=26.0 feet
Parkway well #22 on [0500 to 2300] at 596 gpm
Parkway well #24 on [0500 to 2300] at 405 gpm
(note:Parkway well #26 out of service)
Parkway well #28 on [0500 to 2300] at 601 gpm
Parkway well #29 on [0500 to 2300] at 465 gpm
Parkway well #42 on [0500 to 2300] at 937 gpm
Indian Head well #20 on [0000 to 1300] and [1600 to 2400] at 441 gpm
Route 70, well #31 on [0000 to 2400] at 655 gpm
South Toms River well #32 on [0500 to 2200] at 536 gpm
South Toms River well #38 on [0600 to 0700] at 330 gpm
Berkeley well #33 on [0000 to 1300] and [1500 to 2400] at 903 gpm
Berkeley well #34 on [0600 to 2100] at 897 gpm
Berkeley well #35 on [0100 to 2300] at 620 gpm
|
|
March
|
Indian Hill elevated storage tank in service: Initial WL=22.0 feet
Parkway ground-level storage tank in service (closed in EPANET 2)
(note:Parkway wells pump directly into system and represent Parkway high-service
pump flows
Parkway high-service pump #1 on [0500 to 0700], [1000 to 1800] and [2000
to 2300] at 2,966 gpm
Parkway high-service pump #2 on [0700 to 1000] and [1800 to 2000] at 4,800
gpm
Holiday City ground-level storage tank in service: Initial WL=18.0 feet
Holiday City booster pump off and bypass pipe open from [0000 to 0600]
Holiday City booster pump on (set at 0.87) and bypass pipe closed from
[0600 to 1100]
Holiday City booster pump off and bypass pipe closed from [1100 to 2300]
Holiday City booster pump off and bypass pipe open from [2300 to 2400]
North Dover elevated storage tank in service: Initial WL=30.0 feet
Parkway well #22 on [0500 to 0700], [1000 to 1800] and [2000 to 2300]
at 289 gpm; [0700 to 0900] at 4,800 gpm
Parkway well #24 on [0500 to 0700], [1000 to 1800] and [2000 to 2300]
at 321 gpm; [0900 to 1000] at 4,800 gpm
Parkway well #26 on [0500 to 0700], [1000 to 1800] and [2000 to 2300]
at 570 gpm
Parkway well #28 on [0500 to 0700], [1000 to 1800] and [2000 to 2300]
at 249 gpm; [1800 to 2000] at 4,800 gpm
Parkway well #29 on [0500 to 0700], [1000 to 1800] and [2000 to 2300]
at 776 gpm
Parkway well #42 on [0500 to 0700], [1000 to 1800] and [2000 to 2300]
at 761 gpm
Indian Head well #20 on [0000 to 1300] and [1600 to 2400] at 445 gpm
Route 70, well #31 on [0000 to 2400] at 673 gpm
South Toms River well #32 on [0600 to 1200] at 552 gpm
(note:South Toms River well #38 out of service)
Berkeley well #33 on [0000 to 1400] and [1500 to 2400] at 902 gpm
Berkeley well #34 on [0000 to 2400] at 907 gpm
Berkeley well #35 on [0600 to 1700] at 594 gpm
|
|
April
|
Indian Hill elevated storage tank in service: Initial WL=32.0 feet
Holly ground-level storage tank in service (closed in EPANET 2)
(note:Holly wells pump directly into system and represent Holly high-service
pump flows
Holly high-service pump #1 on [1100 to 1600] at 976 gpm)
Parkway ground-level storage tank in service (closed in EPANET 2)
(note:Parkway wells pump directly into system and represent Parkway
high-service pump flows)
Parkway high-service pump #1 on [0500 to 0700], [1100 to 1800] and [2100
to 2300] at 3,129 gpm
Parkway high-service pump #2 on [0700 to 1100] and [1800 to 2100] at 4,800
gpm
Holiday City ground-level storage tank in service: Initial WL=17.0 feet
Holiday City booster pump off and bypass pipe open from [0000 to 0600]
Holiday City booster pump on (set at 0.87) and bypass pipe closed from
[0600 to 1100]
Holiday City booster pump off and bypass pipe closed from [1100 to 2300]
Holiday City booster pump off and bypass pipe open from [2300 to 2400]
North Dover elevated storage tank in service: Initial WL=35.0 feet
Holly well #30 on [1100 to 1600] at 976 gpm
Parkway well #22 on [0500 to 0700], [1100 to 1800] and [2100 to 2300]
at 309 gpm; on [0700 to 0900] at 4,800 gpm
Parkway well #24 on [0500 to 0700], [1100 to 1800] and [2100 to 2300]
at 421 gpm; on [2000 to 2100] at 4,800 gpm
Parkway well #26 on [0500 to 0700], [1100 to 1800] and [2100 to 2300]
at 1,034 gpm
Parkway well #28 on [0500 to 0700], [1100 to 1800] and [2100 to 2300]
at 296 gpm; on [0900 to 1100] at 4,800 gpm
Parkway well #29 on [0500 to 0700], [1100 to 1800] and [2100 to 2300]
at 76 gpm; on [1800 to 2000] at 4,800 gpm
Parkway well #42 on [0500 to 0700], [1100 to 1800] and [2100 to 2300]
at 993 gpm
Indian Head well #20 on [0000 to 1200] and [1600 to 2400] at 445 gpm
Route 70, well #31 on [0000 to 2400] at 688 gpm
South Toms River well #32 on [0000 to 2400] at 516 gpm
Berkeley well #33 on [0000 to 1400] and [1500 to 2400] at 873 gpm
Berkeley well #34 on [0000 to 2400] at 895 gpm
Berkeley well #35 on [0100 to 2300] at 612 gpm
|
|
May
|
Indian Hill elevated storage tank in service: Initial WL=33.0 feet
Holly ground-level storage tank in service (closed in EPANET 2)
(note: Holly wells pump directly into system and represent Holly high-service
pump flows
Holly high-service pump #1 on [0500 to 2200] at 893 gpm
Holly high-service pump #2 on [0000 to 0500] and [2200 to 2400] at 1,400
gpm)
Parkway ground-level storage tank in service (closed in EPANET 2)
(note:Parkway wells pump directly into system and represent Parkway high-service
pump flows
Parkway high-service pump #1 on [0500 to 0700], [1200 to 1700] and [2100
to 2200] at 2,953 gpm
Parkway high-service pump #2 on [0700 to 1200] and [1700 to 2100] at 4,800
gpm)
Holiday City ground-level storage tank in service: Initial WL=17.0 feet
Holiday City booster pump off and bypass pipe open from [0000 to 0600]
Holiday City booster pump on (set at 0.87) and bypass pipe closed from
[0600 to 1100]
Holiday City booster pump off and bypass pipe closed from [1100 to 2300]
Holiday City booster pump off and bypass pipe open from [2300 to 2400]
North Dover elevated storage tank in service: Initial WL=31.0 feet
Windsor ground-level storage tank in service (closed in EPANET 2)
(note:Windsor well pumps directly into system and represents Windsor
high-service pump flows)
Windsor high-service pump #1 on [0600 to 0800] at 895 gpm)
Holly well #30 on [0500 to 2200] at 893 gpm; on [0000 to 0500] and [2200
to 2400] at 1,400 gpm
Parkway well #22 on [0500 to 0700], [1200 to 1700] and [2100 to 2200]
at 282 gpm; on [0700 to 0900] at 4,800 gpm
Parkway well #24 on [0500 to 0700], [1200 to 1700] and [2100 to 2200]
at 1,173 gpm
Parkway well #26 on [0500 to 0700], [1200 to 1700] and [2100 to 2200]
at 1,148 gpm
Parkway well #28 on [0500 to 0700], [1200 to 1700] and [2100 to 2200]
at 105 gpm; on [0900 to 1100] at 4,800 gpm
Parkway well #29 on [0500 to 0700], [1200 to 1700] and [2100 to 2200]
at 90 gpm; on [1900 to 2100] at 4,800 gpm
Parkway well #42 on [0500 to 0700], [1200 to 1700] and [2100 to 2200]
at 155 gpm; on [1100 to 1200] and [1700 to 1900] at 4,800 gpm
Indian Head well #20 on [0000 to 1200] and [1600 to 2400] at 437 gpm
Route 70, well #31 on [0000 to 2400] at 679 gpm
South Toms River well #32 on [0000 to 2400] at 541 gpm
Berkeley well #33 on [0000 to 1300] and [1600 to 2400] at 908 gpm
Berkeley well #34 on [0000 to 2400] at 901 gpm
Berkeley well #35 on [0000 to 2300] at 614 gpm
Windsor well #40 on [0600 to 0800] at 895 gpm
|
|
June
|
Parkway high-service pump #2 on [0600 to 1200] and [1700 to 2200] at
4,800 gpm)
Holiday City ground-level storage tank in service: Initial WL=17.0 feet
Holiday City booster pump off and bypass pipe open from [0000 to 0600]
Holiday City booster pump on (set at 0.87) and bypass pipe closed from
[0600 to 1100]
Holiday City booster pump off and bypass pipe closed from [1100 to 2300]
Holiday City booster pump off and bypass pipe open from [2300 to 2400]
North Dover elevated storage tank in service: Initial WL=32.0 feet
Windsor ground-level storage tank in service (closed in EPANET 2)
(note:Windsor well pumps directly into system and represents Windsor
high-service pump flows)
Windsor high-service pump #1 on [0600 to 1300] at 1,000 gpm)
Holly well #30 on [0000 to 0600] and [1700 to 2400] at 1,400 gpm; [0600
to 1700] at 2,048 gpm
Holly well #37 on [0600 to 1700] at 133 gpm
Parkway well #22 on [0400 to 0600] and [1200 to 1700] at 613 gpm;[0600
to 0800] at 4,800 gpm
Parkway well #24 on [0400 to 0600] and [1200 to 1700] at 1,373 gpm
Parkway well #26 on [0400 to 0600] and [1200 to 1700] at 302 gpm;[0800
to 1000] at 4,800 gpm
Parkway well #28 on [0400 to 0600] and [1200 to 1700] at 287 gpm;[1000
to 1200] at 4,800 gpm
Parkway well #29 on [0400 to 0600] and [1200 to 1700] at 181 gpm;[1700
to 1900] at 4,800 gpm
Parkway well #42 on [0400 to 0600] and [1200 to 1700] at 95 gpm; [1900
to 2200] at 4,800 gpm
Brookside well #15 on [0000 to 0100] and [2300 to 2400] at 812 gpm
Indian Head well #20 on [0000 to 1200] and [1700 to 2400] at 453 gpm
Route 70, well #31 on [0000 to 2400] at 684 gpm
South Toms River well #32 on [0300 to 2300] at 522 gpm
South Toms River well #38 on [0600 to 1000] at 559 gpm
Berkeley well #33 on [0000 to 1300] and [1500 to 2400] at 871 gpm
Berkeley well #34 on [0000 to 2400] at 938 gpm
Berkeley well #35 on [0000 to 2300] at 623 gpm
Windsor well #40 on [0600 to 1300] at 1,000 gpm
|
|
July
|
Indian Hill elevated storage tank in service: Initial WL=31.0 feet
Holly ground-level storage tank in service (closed in EPANET 2)
(note:Holly wells pump directly into system and represent Holly high-service
pump flows)
Holly high-service pump #1 on [0600 to 0900], [1100 to 1800] and [2000
to 2200] at 900 gpm
Holly high-service pump #2 on [0600 to 0900], [1100 to 1800] and [2000
to 2200] at 1,290 gpm; on [0000 to 0600] and [2200 to 2400] at 1,390 gpm
Holly high-service pump #3 on [0900 to 1100] and [1800 to 2000] at 2,790
gpm)
Parkway ground-level storage tank in service (closed in EPANET 2)
(note:Parkway wells pump directly into system and represent Parkway
high-service pump flows)
Parkway high-service pump #1 on [0400 to 0600] and [1200 to 1700] at 3,095
gpm
Parkway high-service pump #2 on [0600 to 1200] and [1700 to 2200] at 4,800
gpm)
Holiday City ground-level storage tank in service: Initial WL=17.0 feet
Holiday City booster pump off and bypass pipe open from [0000 to 0600]
Holiday City booster pump on (set at 0.87) and bypass pipe closed from
[0600 to 1100]
Holiday City booster pump off and bypass pipe closed from [1100 to 2300]
Holiday City booster pump off and bypass pipe open from [2300 to 2400]
North Dover elevated storage tank in service: Initial WL=32.0 feet
Windsor ground-level storage tank in service (closed in EPANET 2)
(note:Windsor well pumps directly into system and represents Windsor
high-service pump flows)
Windsor high-service pump #1 on [0600 to 1200] at 999 gpm)
Holly well #30 on [0000 to 0600] and [2200 to 2400] at 1,173 gpm; on [0600
to 0900], [1100 to 1800] and [2000 to 2200] at 2,190 gpm; on [0900 to
1100] and [1800 to 2000] at 2,790 gpm
Holly well #37 on [0000 to 0600] and [2200 to 2400] at 216 gpm
Parkway well #22 on [0400 to 0600] and [1200 to 1700] at 602 gpm; [0600
to 0800] at 4,800 gpm
Parkway well #24 on [0400 to 0600] and [1200 to 1700] at 1,365 gpm
Parkway well #26 on [0400 to 0600] and [1200 to 1700] at 293 gpm; [0800
to 1000] at 4,800 gpm
Parkway well #28 on [0400 to 0600] and [1200 to 1700] at 308 gpm; [1000
to 1200] at 4,800 gpm
Parkway well #29 on [0400 to 0600] and [1200 to 1700] at 223 gpm; [2000
to 2200] at 4,800 gpm
Parkway well #42 on [0400 to 0600] and [1200 to 1700] at 305 gpm; [1700
to 2000] at 4,800 gpm
Brookside well #15 on [0000 to 0500] at 696 gpm
Indian Head well #20 on [0000 to 1200] and [1600 to 2400] at 436 gpm
Route 70, well #31 on [0000 to 2400] at 681 gpm
South Toms River well #32 on [0500 to 2300] at 537 gpm
South Toms River well #38 on [0400 to 2300] at 523 gpm
Berkeley well #33 on [0000 to 1200] and [1600 to 2400] at 898 gpm
Berkeley well #34 on [0000 to 2400] at 942 gpm
Berkeley well #35 on [0000 to 2300] at 624 gpm
Windsor well #40 on [0600 to 1200] at 999 gpm
|
|
August
(Maximum-Demand Month)
|
Indian Hill elevated storage tank in service: Initial WL=34.0 feet
Holly ground-level storage tank in service (closed in EPANET 2)
(note:Holly wells pump directly into system and represent Holly high-service
pump flows)
Holly high-service pump #1 on [0500 to 0800], [1200 to 1700] and [2100
to 2400] at 900 gpm
Holly high-service pump #2 on [0500 to 0800], [1200 to 1700] and [2100
to 2400] at 1,300 gpm; on [0000 to 0500] at 1,492 gpm
Holly high-service pump #3 on [0800 to 1200] and [1700 to 2100] at 3,000
gpm)
Parkway ground-level storage tank in service (closed in EPANET 2)
(note:Parkway wells pump directly into system and represent Parkway
high-service pump flows)
Parkway high-service pump #1 on [0400 to 0600], [1200 to 1700] and [2200
to 2300] at 3,180 gpm
Parkway high-service pump #2 on [0600 to 1200] and [1700 to 2200] at 4,800
gpm)
Holiday City ground-level storage tank in service: Initial WL=17.0 feet
Holiday City booster pump off and bypass pipe open from [0000 to 0600]
Holiday City booster pump on (set at 0.87) and bypass pipe closed from
[0600 to 1100]
Holiday City booster pump off and bypass pipe closed from [1100 to 2300]
Holiday City booster pump off and bypass pipe open from [2300 to 2400]
North Dover elevated storage tank in service: Initial WL=22.0 feet
Windsor ground-level storage tank in service (closed in EPANET 2)
(note:Windsor well pumps directly into system and represents Windsor
high-service pump flows)
Windsor high-service pump #1 on [0000 to 2400] at 1,166 gpm)
Holly well #30 on [0000 to 0500] at 29 gpm; on [0500 to 0800], [1200 to
1700] and [2100 to 2400] at 2,200 gpm; on [0800 to 1200] and [1700 to
2100] at 3,000 gpm
Holly well #37 on [0000 to 0500] at 1,463 gpm
Parkway well #22 on [0400 to 0600], [1200 to 1700] and [2200 to 2300]
at 583 gpm; on [0600 to 0800] at 4,800
Parkway well #24 on [0400 to 0600], [1200 to 1700] and [2200 to 2300]
at 60 gpm; on [0800 to 1000] at 4,800 gpm
Parkway well #26 on [0400 to 0600], [1200 to 1700] and [2200 to 2300]
at 247 gpm; on [1000 to 1200] at 4,800
Parkway well #28 on [0400 to 0600], [1200 to 1700] and [2200 to 2300]
at 787 gpm; on [2100 to 2200] at 4,800
Parkway well #29 on [0400 to 0600], [1200 to 1700] and [2200 to 2300]
at 1,383 gpm
Parkway well #42 on [0400 to 0600], [1200 to 1700] and [2200 to 2300]
at 118 gpm; on [1700 to 2100] at 4,800
Brookside well #15 on [0000 to 1300] and [2200 to 2400] at 677 gpm
Indian Head well #20 on [0000 to 1700] and [2100 to 2400] at 439 gpm
Route 70, well #31 on [0000 to 2400] at 681 gpm
South Toms River well #32 on [0200 to 2300] at 531 gpm
South Toms River well #38 on [0500 to 2200] at 717 gpm
Berkeley well #33 on [0000 to 1500] and [1800 to 2400] at 877 gpm
Berkeley well #34 on [0000 to 2400] at 959 gpm
Berkeley well #35 on [0000 to 2300] at 624 gpm
Windsor well #40 on [0000 to 2400] at 1,166 gpm
|
|
September
|
Indian Hill elevated storage tank in service: Initial WL=33.0 feet
Holly ground-level storage tank in service (closed in EPANET 2)
(note:Holly wells pump directly into system and represent Holly high-service
pump flows)
Holly high-service pump #1 on [0600 to 2000] at 900 gpm
Holly high-service pump #2 on [0600 to 2000] at 1,310 gpm; [0000 to 0600]
and [2000 to 2400] at 1,409 gpm)
Parkway ground-level storage tank in service (closed in EPANET 2)
(note Parkway wells pump directly into system and represent Parkway
high-service pump flows)
Parkway high-service pump #1 on [0500 to 0700], [1200 to 1700] and [2100
to 2200] at 3,002 gpm
Parkway high-service pump #2 on [0700 to 1200] and [1700 to 2100] at 4,800
gpm)
Holiday City ground-level storage tank in service: Initial WL=17.0 feet
Holiday City booster pump off and bypass pipe open from [0000 to 0600]
Holiday City booster pump on (set at 0.87) and bypass pipe closed from
[0600 to 1100]
Holiday City booster pump off and bypass pipe closed from [1100 to 2300]
Holiday City booster pump off and bypass pipe open from [2300 to 2400]
North Dover elevated storage tank in service: Initial WL=34.0 feet
Windsor ground-level storage tank in service (closed in EPANET 2)
(note:Windsor well pumps directly into system and represents Windsor
high-service pump flows)
Windsor high-service pump #1 on [0600 to 1400] at 990 gpm)
Holly well #30 on [0000 to 0600] and [2000 to 2400] at 1381 gpm; [0600
to 2000] at 2,210 gpm
Holly well #37 on [0000 to 0600] and [2000 to 2400] at 28 gpm
Parkway well #22 on [0500 to 0700], [1200 to 1700] and [2100 to 2200]
at 400 gpm; on [0700 to 0900] at 4,800 gpm
Parkway well #24 on [0500 to 0700], [1200 to 1700] and [2100 to 2200]
at 1,099 gpm
Parkway well #26 on [0500 to 0700], [1200 to 1700] and [2100 to 2200]
at 35 gpm; on [0900 to 1100] at 4,800 gpm
Parkway well #28 on [0500 to 0700], [1200 to 1700] and [2100 to 2200]
at 30 gpm; on [1100 to 1200] and [1700 to 1800] at 4,800 gpm
Parkway well #29 on [0500 to 0700], [1200 to 1700] and [2100 to 2200]
at 1,333 gpm
Parkway well #42 on [0500 to 0700], [1200 to 1700] and [2100 to 2200]
at 105 gpm; on [1800 to 2100] at 4,800 gpm
Brookside well #15 on [0000 to 0700] and [2100 to 2400] at 687 gpm
Indian Head well #20 on [0000 to 1200] and [1600 to 2400] at 441 gpm
Route 70, well #31 on [0000 to 2400] at 683 gpm
South Toms River well #32 on [0600 to 2100] at 535 gpm
South Toms River well #38 on [0600 to 1800] at 514 gpm
Berkeley well #33 on [0000 to 1300] and [1600 to 2400] at 886 gpm
Berkeley well #34 on [0000 to 2400] at 946 gpm
Berkeley well #35 on [0000 to 2300] at 632 gpm
Windsor well #40 on [0600 to 1400] at 990 gpm
|
|
October
(Average-Demand Month)
|
Indian Hill elevated storage tank in service: Initial WL=28.0 feet
Holly ground-level storage tank in service (closed in EPANET 2)
(note:Holly wells pump directly into system and represent Holly high-service
pump flows)
Holly high-service pump #1 on [0100 to 2300] at 920 gpm)
Parkway ground-level storage tank in service (closed in EPANET 2)
(note:Parkway wells pump directly into system and represent Parkway
high-service pump flows
Parkway high-service pump #1 on [0500 to 0700], [1000 to 1800] and [2000
to 2200] at 3,102 gpm
Parkway high-service pump #2 on [0700 to 1000] and [1800 to 2000] at 4,800
gpm)
Holiday City ground-level storage tank in service: Initial WL=17.0 feet
Holiday City booster pump off and bypass pipe open from [0000 to 0600]
Holiday City booster pump on (set at 0.87) and bypass pipe closed from
[0600 to 1100]
Holiday City booster pump off and bypass pipe closed from [1100 to 2300]
Holiday City booster pump off and bypass pipe open from [2300 to 2400]
North Dover elevated storage tank in service: Initial WL=35.0 feet
Windsor ground-level storage tank in service (closed in EPANET 2)
(note:Windsor well pumps directly into system and represents Windsor
high-service pump flows)
Windsor high-service pump #1 on [0600 to 1200] at 932 gpm
Holly well #30 on [0100 to 2300] at 920 gpm
(note:Holly well #37 out of service)
Parkway well #22 on [0500 to 0700], [1000 to 1800] and [2000 to 2200]
at 60 gpm; on [0700 to 1000] at 4,800 gpm
Parkway well #24 on [0500 to 0700], [1000 to 1800] and [2000 to 2200]
at 603 gpm
Parkway well #26 on [0500 to 0700], [1000 to 1800] and [2000 to 2200]
at 97 gpm; on [1800 to 2000] at 4,800 gpm
Parkway well #28 on [0500 to 0700], [1000 to 1800] and [2000 to 2200]
at 858 gpm
Parkway well #29 on [0500 to 0700], [1000 to 1800] and [2000 to 2200]
at 969 gpm
Parkway well #42 on [0500 to 0700], [1000 to 1800] and [2000 to 2200]
at 514 gpm
(note:Brookside well #15 out of service)
Indian Head well #20 on [0000 to 1200] and [1600 to 2400] at 448 gpm
Route 70, well #31 on [0000 to 2400] at 680 gpm
(note:South Toms River well #32 out of service)
(note:South Toms River well #38 out of service)
Berkeley well #33 on [0000 to 1400] and [1500 to 2400] at 871 gpm
Berkeley well #34 on [0000 to 2400] at 961 gpm
Berkeley well #35 on [0000 to 2300] at 605 gpm
Windsor well #40 on [0600 to 1200] at 932 gpm
|
|
November
|
Indian Hill elevated storage tank in service: Initial WL=20.0 feet
note: Holly ground-level storage tank out of service)
Parkway ground-level storage tank in service (closed in EPANET 2)
(note: Parkway wells pump directly into system and represent Parkway
high-service pump flows)
Parkway high-service pump #1 on [0500 to 0700], [1000 to 1800] and [2000
to 2300] at 2,950 gpm
Parkway high-service pump #2 on [0700 to 1000] and [1800 to 2000] at 4,800
gpm)
Holiday City ground-level storage tank in service: Initial WL=17.0 feet
Holiday City booster pump off and bypass pipe open from [0000 to 0600]
Holiday City booster pump on (set at 0.87) and bypass pipe closed from
[0600 to 1100]
Holiday City booster pump off and bypass pipe closed from [1100 to 2300]
Holiday City booster pump off and bypass pipe open from [2300 to 2400]
North Dover elevated storage tank in service: Initial WL=27.0 feet
Windsor ground-level storage tank in service (closed in EPANET 2)
(note:Windsor well pumps directly into system and represents Windsor
high-service pump flows)
Windsor high-service pump #1 on [0600 to 0900] at 1,073 gpm)
(note:Holly well #30 out of service)
Parkway well #22 on [0500 to 0700], [1000 to 1800] and [2000 to 2300]
at 81 gpm; on [0700 to 1000] at 4,800 gpm
Parkway well #24 on [0500 to 0700], [1000 to 1800] and [2000 to 2300]
at 631 gpm
Parkway well #26 on [0500 to 0700], [1000 to 1800] and [2000 to 2300]
at 153 gpm; on [1800 to 2000] at 4,800 gpm
Parkway well #28 on [0500 to 0700], [1000 to 1800] and [2000 to 2300]
at 821 gpm
Parkway well #29 on [0500 to 0700], [1000 to 1800] and [2000 to 2300]
at 932 gpm
Parkway well #42 on [0500 to 0700], [1000 to 1800] and [2000 to 2300]
at 332 gpm
Indian Head well #20 on [0000 to 1200] and [1600 to 2400] at 454 gpm
Route 70, well #31 on [0000 to 2400] at 667 gpm
Berkeley well #33 on [0000 to 1400] and [1500 to 2400] at 876 gpm
Berkeley well #34 on [0000 to 2400] at 1,014 gpm
Berkeley well #35 on [0000 to 2400] at 616 gpm
Windsor well #40 on [0600 to 0900] at 1,073 gpm
|
|
December
|
Indian Hill elevated storage tank in service: Initial WL=20.0 feet
Parkway ground-level storage tank in service (closed in EPANET 2)
(note:Parkway wells pump directly into system and represent Parkway
high-service pump flows)
Parkway high-service pump #1 on [0500 to 0700], [1000 to 1800] and [2000
to 2300] at 2,890 gpm
Parkway high-service pump #2 on [0700 to 1000] and [1800 to 2000] at 4,800
gpm)
Holiday City ground-level storage tank in service: Initial WL=17.0 feet
Holiday City booster pump off and bypass pipe open from [0000 to 0600]
Holiday City booster pump on (set at 0.87) and bypass pipe closed from
[0600 to 1100]
Holiday City booster pump off and bypass pipe closed from [1100 to 2300]
Holiday City booster pump off and bypass pipe open from [2300 to 2400]
(note:Windsor ground-level storage tank out of service)
North Dover elevated storage tank in service: Initial WL=26.0 feet
Parkway well #22 on [0500 to 0700], [1000 to 1800] and [2000 to 2300]
at 6 gpm; on [0700 to 1000] at 4,800 gpm
Parkway well #24 on [0500 to 0700], [1000 to 1800] and [2000 to 2300]
at 201 gpm
Parkway well #26 on [0500 to 0700], [1000 to 1800] and [2000 to 2300]
at 732 gpm
Parkway well #28 on [0500 to 0700], [1000 to 1800] and [2000 to 2300]
at 37 gpm; on [1800 to 2000] at 4,800 gpm
Parkway well #29 on [0500 to 0700], [1000 to 1800] and [2000 to 2300]
at 837 gpm
Parkway well #42 on [0500 to 0700], [1000 to 1800] and [2000 to 2300]
at 1,077 gpm
Indian Head well #20 on [0000 to 1200] and [1600 to 2400] at 444 gpm
Route 70, well #31 on [0000 to 1400] and [1500 to 2400] at 704 gpm
South Toms River well #32 on [0600 to 1000] at 613 gpm
Berkeley well #33 on [0000 to 1200] and [1600 to 2400] at 985 gpm
Berkeley well #34 on [0000 to 2400] at 1,002 gpm
Berkeley well #35 on [0200 to 2300] at 704 gpm
(note:Windsor well #40 out of service)
|
|
Month
|
Description of Operations
|
|
January
|
Indian Hill elevated storage tank in service: Initial WL=19.0 feet
Parkway ground-level storage tank in service (closed in EPANET 2)
(note:Parkway wells pump directly into system and represent Parkway
high-service pump flows)
Parkway high-service pump #1 on [0500 to 0700], [1000 to 1800], [2000
to 2200] at 3,039 gpm
Parkway high-service pump #2 on [0700 to 1000] and [1800 to 2000] at 4,800
gpm)
Holiday City ground-level storage tank in service: Initial WL=17.0
Holiday City booster pump off and bypass pipe open [0000 to 0600]
Holiday City booster pump on (set at 0.87) and bypass pipe closed [0600
to 1100]
Holiday City booster pump off and bypass pipe closed [1100 to 2300]
Holiday City booster pump off and bypass pipe open [2300 to 2400]
North Dover elevated storage tank in service: Initial WL=31.0 feet
Parkway well #22 on [0500 to 0700] at 23 gpm, [0700 to 0900] at 4,800
gpm, [1000 to 1800] and [2000 to 2200] at 23 gpm
Parkway well #24 on [0500 to 0700], [1000 to 1800], [2000 to 2200] at
496 gpm
Parkway well #26 on [0500 to 0700], [1000 to 1800], [2000 to 2200] at
820 gpm
Parkway well #28 on [0500 to 0700], [1000 to 1800], [2000 to 2200] at
86 gpm, [0900 to 1000] and [1800 to 1900] at 4,800 gpm
Parkway well #29 on [0500 to 0700] and [1000 to 1800] at 523 gpm, [1900
to 2000] at 4,800 gpm and [2000 to 2200] at 523 gpm
Parkway well #42 on [0500 to 0700], [1000 to 1800], [2000 to 2200] at
1,091 gpm
Indian Head well #20 on [0000 to 1200] and [1600 to 2400] at 448 gpm
Route 70, well #31 on [0000 to 2400] at 667 gpm
South Toms River well #32 on [0600 to 1400] at 563 gpm
Berkeley well #33 on [0000 to 1300] and [1500 to 2400] at 886 gpm
Berkeley well #34 on [0000 to 2400] at 1,001 gpm
Berkeley well #35 on [0400 to 2200] at 641 gpm
|
|
February
(Minimum-Demand Month)
|
Indian Hill elevated storage tank in service: Initial WL=22.0 feet
Parkway ground-level storage tank in service (closed in EPANET 2)
(note:Parkway wells pump directly into system and represent Parkway
high-service pump flows)
Parkway high-service pump #1 on [0500 to 0600], [1100 to 1700], [2100
to 2300] at 3,028 gpm
Parkway high-service pump #2 on [0600 to 1100] and [1700 to 2100] at 4,800
gpm)
Holiday City ground-level storage tank in service: Initial WL=17.0
Holiday City booster pump off and bypass pipe open [0000 to 0600]
Holiday City booster pump on (set at 0.87) and bypass pipe closed [0600
to 1100]
Holiday City booster pump off and bypass pipe closed [1100 to 2300]
Holiday City booster pump off and bypass pipe open [2300 to 2400]
North Dover elevated storage tank in service: Initial WL=29.0 feet
Parkway well #22 on [0500 to 0600], [1100 to 1700], [2100 to 2300] at
41 gpm,[0600 to 0900] at 4,800 gpm
Parkway well #24 on [0500 to 0600], [1100 to 1700], [2100 to 2300] at
9 gpm, [0900 to 1100] at 4,800 gpm
Parkway well #26 on [0500 to 0600], [1100 to 1700], [2100 to 2300] at
49 gpm; [1700 to 1900] at 4,800 gpm
Parkway well #28 on [0500 to 0600], [1100 to 1700], [2100 to 2300] at
118 gpm, [1900 to 2100] at 4,800 gpm
Parkway well #29 on [0500 to 0600], [1100 to 1700], [2100 to 2300] at
1,244 gpm
Parkway well #42 on [0500 to 0600], [1100 to 1700], [2100 to 2300] at
1,567 gpm
Indian Head well #20 on [0000 to 1200] and [1600 to 2400] at 454 gpm
Route 70, well #31 on [0000 to 2400] at 657 gpm
South Toms River well #32 on [0600 to 1500] at 514 gpm
Berkeley well #33 on [0000 to 1200] and [1600 to 2400] at 900 gpm
Berkeley well #34 on [0000 to 2400] at 959 gpm
(note:Berkeley well #35 out of service)
|
|
March
|
Indian Hill elevated storage tank in service: Initial WL=20.0 feet
Holly ground-level storage tank in service (closed in EPANET 2)
(note:Holly wells pump directly into system and represent Holly high-service
pump flows)
Holly high-service pump #1 on [0600 to 1500] at 917 gpm)
Parkway ground-level storage tank in service (closed in EPANET 2)
(note:Parkway wells pump directly into system and represent Parkway
high-service pump flows)
Parkway high-service pump #1 on [0500 to 0700], [1100 to 1800], [2100
to 2300] at 3,007 gpm
Parkway high-service pump #2 on [0700 to 1100] and [1800 to 2100] at 4,800
gpm
Holiday City ground-level storage tank in service: Initial WL=17.0
Holiday City booster pump off and bypass pipe open [0000 to 0600]
Holiday City booster pump on (set at 0.87) and bypass pipe closed [0600
to 1100]
Holiday City booster pump off and bypass pipe closed [1100 to 2300]
Holiday City booster pump off and bypass pipe open [2300 to 2400]
North Dover elevated storage tank in service: Initial WL=27.0 feet
Holly well #30 on [0600 to 1500] at 917 gpm
Parkway well #22 on [0500 to 0700], [1100 to 1800], [2100 to 2300] at
18 gpm, [0700 to 1000] at 4,800 gpm
Parkway well #24 on [0500 to 0700], [1100 to 1800], [2100 to 2300] at
1gpm, [1000 to 1100] and [1800 to 1900] at 4,800 gpm
Parkway well #26 on [0500 to 0700], [1100 to 1800], [2100 to 2300] at
764 gpm
Parkway well #28 on [0500 to 0700], [1100 to 1800], [2100 to 2300] at
67 gpm, [1900 to 2100] at 4,800 gpm
Parkway well #29 on [0500 to 0700], [1100 to 1800], [2100 to 2300] at
1,005 gpm
Parkway well #42 on [0500 to 0700], [1100 to 1800], [2100 to 2300] at
1,152 gpm
Indian Head well #20 on [0000 to 1200] and [1600 to 2400] at 443 gpm
Route 70, well #31 on [0000 to 2400] at 674 gpm
South Toms River well #32 on [0600 to 1800] at 527 gpm
Berkeley well #33 on [0000 to 1200] and [1600 to 2400] at 899 gpm
Berkeley well #34 on [0000 to 2400] at 915 gpm
|
|
April
|
Indian Hill elevated storage tank in service: Initial WL=26.0 feet
Holly ground-level storage tank in service (closed in EPANET 2)
(note:Holly wells pump directly into system and represent Holly high-service
pump flows)
Holly high-service pump #1 on [0600 to 1600] at 900 gpm
Holly high-service pump #2 on [0600 to 1600] at 1,282 gpm, [0000 to 0600]
and [1600 to 2400] at 1,382 gpm)
Parkway ground-level storage tank in service (closed in EPANET 2)
(note:Parkway wells pump directly into system and represent Parkway
high-service pump flows)
Parkway high-service pump #1 on [0500 to 0700], [1000 to 1800], [2000
to 2200] at 3,058 gpm
Parkway high-service pump #2 on [0700 to 1000] and [1800 to 2000] at 4,800
gpm
Holiday City ground-level storage tank in service: Initial WL=17.0
Holiday City booster pump off and bypass pipe open [0000 to 0600]
Holiday City booster pump on (set at 0.87) and bypass pipe closed [0600
to 1100]
Holiday City booster pump off and bypass pipe closed [1100 to 2300]
Holiday City booster pump off and bypass pipe open [2300 to 2400]
North Dover elevated storage tank in service: Initial WL=23.0 feet
Holly well #30 on [0000 to 0600] and [1600 to 2400] at 1,383 gpm, [0600
to 1600] at 2,182 gpm
Parkway well #22 on [0500 to 0700], [1000 to 1800], [2000 to 2200] at
379 gpm, [0700 to 0900] at 4,800 gpm
Parkway well #24 on [0500 to 0700], [1000 to 1800], [2000 to 2200] at
786 gpm
Parkway well #26 on [0500 to 0700], [1000 to 1800], [2000 to 2200] at
826 gpm
Parkway well #28 on [0500 to 0700], [1000 to 1800], [2000 to 2200] at
39 gpm, [0900 to 1000] and [1800 to 1900] at 4,800 gpm
Parkway well #29 on [0500 to 0700], [1000 to 1800], [2000 to 2200] at
402 gpm, [1900 to 2000] at 4,800 gpm
Parkway well #42 on [0500 to 0700], [1000 to 1800], [2000 to 2200] at
626 gpm
Indian Head well #20 on [0000 to 0700] and [2200 to 2400] at 464 gpm
Route 70, well #31 on [0000 to 0600] and [2300 to 2400] at 673 gpm
South Toms River well #32 on [0300 to 2300] at 526 gpm
Berkeley well #33 on [0000 to 1200] and [1700 to 2400] at 883 gpm
Berkeley well #34 on [0000 to 2300] at 900 gpm
|
|
May
|
Indian Hill elevated storage tank in service: Initial WL=31.0 feet
Holly ground-level storage tank in service (closed in EPANET 2)
(note:Holly wells pump directly into system and represent Holly high-service
pump flows)
Holly high-service pump #1 on [05:00 to 22:00] at 900 gpm
Holly high-service pump #2 on [05:00 to 22:00] at 1,312 gpm, [00:00 to
05:00] and [22:00 to 24:00] at 1,413 gpm)
Parkway ground-level storage tank in service (closed in EPANET 2)
(note:Parkway wells pump directly into system and represent Parkway
high-service pump flows)
Parkway high-service pump #1 on [05:00 to 06:00], [12:00 to 17:00], [22:00
to 23:00] at 2,933 gpm
Parkway high-service pump #2 on [06:00 to 12:00] and [17:00 to 22:00]
at 4,800 gpm)
Holiday City ground-level storage tank in service: Initial WL=16.0
Holiday City booster pump off and bypass pipe open [00:00 to 06:00]
Holiday City booster pump on (set at 0.87) and bypass pipe closed [06:00
to 11:00]
Holiday City booster pump off and bypass pipe closed [11:00 to 23:00]
Holiday City booster pump off and bypass pipe open [23:00 to 24:00]
Windsor ground-level storage tank in service (closed in EPANET 2)
(note:Windsor well pumps directly into system and represents Windsor
high-service pump flows)
Windsor high-service pump #1 on [06:00 to 18:00] at 981 gpm)
North Dover elevated storage tank in service: Initial WL=21.0 feet
Holly well #30 on [00:00 to 05:00] at 1,235 gpm, [05:00 to 22:00] at 2212
gpm,[22:00 to 24:00] at 1,235 gpm
Holly well #37 on [00:00 to 05:00] and [22:00 to 24:00] at 179 gpm
Parkway well #22 on [0500 to 0600], [1200 to 1700], [2200 to 2300] at
94 gpm, [0600 to 0900] at 4,800 gpm
Parkway well #24 on [0500 to 0600], [1200 to 1700], [2200 to 2300] at
1,442 gpm
Parkway well #26 on [0500 to 0600], [1200 to 1700] and [2200 to 2300]
at 113 gpm, [2000 to 2200] at 4,800 gpm
Parkway well #28 on [0500 to 0600], [1200 to 1700] and [2200 to 2300]
at 138 gpm, [1800 to 2000] at 4,800 gpm
Holly well #37 on [0000 to 0500] and [2200 to 2400] at 179 gpm
Parkway well #22 on [0500 to 0600], [1200 to 1700], [2200 to 2300] at
94 gpm, [0600 to 0900] at 4,800 gpm
Parkway well #24 on [0500 to 0600], [1200 to 1700], [2200 to 2300] at
1,442 gpm
Parkway well #26 on [0500 to 0600], [1200 to 1700] and [2200 to 2300]
at 113 gpm, [2000 to 2200] at 4,800 gpm
Parkway well #28 on [0500 to 0600], [1200 to 1700] and [2200 to 2300]
at 138 gpm, [1800 to 2000] at 4,800 gpm
Parkway well #29 on [0500 to 0600], [1200 to 1700], [2200 to 2300] at
1,056 gpm
Parkway well #42 on [0500 to 0600], [1200 to 1700] and [2200 to 2300]
at 89 gpm, [0900 to 1200] and [1700 to 1800] at 4,800 gpm
Brookside well #15 on [0000 to 0400] at 698 gpm
Indian Head well #20 on [0000 to 0200] at 408 gpm
Route 70, well #31 on [0000 to 0500] and [2200 to 2400] at 724 gpm
South Toms River well #32 on [0500 to 2300] at 531 gpm
South Toms River well #38 on [0600 to 0700] at 182 gpm
Berkeley well #33 on [0000 to 1300] and [1800 to 2400] at 879 gpm
Berkeley well #34 on [0000 to 2400] at 922 gpm
Berkeley well #35 on [0000 to 0100] at 231 gpm
Windsor well #40 on [0600 to 1800] at 981 gpm
|
|
June
(Maximum-Demand Month)
|
Indian Hill elevated storage tank in service: Initial WL=31.0 feet
Holly ground-level storage tank in service (closed in EPANET 2)
(note:Holly wells pump directly into system and represent Holly high-service
pump flows)
Holly high-service pump #1 on [0600 to 2100] at 900 gpm
Holly high-service pump #2 on [0600 to 2100] at 1,300 gpm, [0000 to 0600]
and [2100 to 2400] at 1,400 gpm)
Parkway ground-level storage tank in service (closed in EPANET 2)
(note:Parkway wells pump directly into system and represent Parkway
high-service pump flows)
Parkway high-service pump #1 on [0500 to 0600] and [1100 to 1700] at 3,103
gpm
Parkway high-service pump #2 on [0600 to 1100] and [1700 to 2200] at 4,800
gpm)
Holiday City ground-level storage tank in service: Initial WL=16.0
Holiday City booster pump off and bypass pipe open [0000 to 0600]
Holiday City booster pump on (set at 0.87) and bypass pipe closed [0600
to 1100]
Holiday City booster pump off and bypass pipe closed [1100 to 2300]
Holiday City booster pump off and bypass pipe open [2300 to 2400]
Windsor ground-level storage tank in service (closed in EPANET 2)
(note:Windsor well pumps directly into system and represents Windsor
high-service pump flows)
Windsor high-service pump #1 on [0000 to 2400] at 1,148 gpm)
North Dover elevated storage tank in service: Initial WL=25.0 feet
Holly well #30 on [0000 to 0600] at 1400 gpm, [0600 to 2100] at 2,200
gpm, [2100 to 2400] at 1,400 gpm;
(note:Holly well #37 out of service)
Parkway well #22 on [0500 to 0600] and [1100 to 1700] at 553 gpm, [0600
to 0800] at 4,800 gpm
Parkway well #24 on [0500 to 0600] and [1100 to 1700] at 600 gpm, [0800
to 0900] at 4,800 gpm
Parkway well #26 on [0500 to 0600] and [1100 to 1700] at 646 gpm, [0900
to 1000] at 4,800 gpm
Parkway well #28 on [0500 to 0600] and [1100 to 1700] at 677 gpm, [1000
to 1100] at 4,800 gpm
Parkway well #29 on [0500 to 0600] and [1100 to 1700] at 281 gpm, [1700
to 1800] at 4,800 gpm
Parkway well #42 on [0500 to 0600] and [1100 to 1700] at 346 gpm, [1800
to 2200] at 4,800 gpm
Brookside well #15 on [0000 to 0400] at 760 gpm
(note: Indian Head well #20 out of service)
Route 70, well #31 on [0000 to 2400] at 671 gpm
South Toms River well #32 on [0700 to 1800] at 526 gpm
South Toms River well #38 on [0700 to 1700] at 696 gpm
Berkeley well #33 on [0000 to 1200] and [1600 to 2400] at 898 gpm
Berkeley well #34 on [0000 to 2400] at 934 gpm
Berkeley well #35 on [0000 to 2400] at 681 gpm
Windsor well #40 on [0000 to 2400] at 1,148 gpm
|
|
July
|
Indian Hill elevated storage tank in service: Initial WL=32.0 feet
Holly ground-level storage tank in service (closed in EPANET 2)
(note:Holly wells pump directly into system and represent Holly high-service
pump flows)
Holly high-service pump #1 on [0600 to 2000] at 900 gpm
Holly high-service pump #2 on [0600 to 2000] at 1,304 gpm, [0000 to 0600]
and [2000 to 2400] at 1,404 gpm)
Parkway ground-level storage tank in service (closed in EPANET 2)
(note:Parkway wells pump directly into system and represent Parkway
high-service pump flows)
Parkway high-service pump #1 on [0500 to 0700], [1000 to 1900], [2100
to 2200] at 2,889 gpm
Parkway high-service pump #2 on [0700 to 1000] and [1900 to 2100] at 4,800
gpm)
Holiday City ground-level storage tank in service: Initial WL=16.0
Holiday City booster pump off and bypass pipe open [0000 to 0600]
Holiday City booster pump on (set at 0.87) and bypass pipe closed [0600
to 1100]
Holiday City booster pump off and bypass pipe closed [1100 to 2300]
Holiday City booster pump off and bypass pipe open [2300 to 2400]
Windsor ground-level storage tank in service (closed in EPANET 2)
(note:Windsor well pumps directly into system and represents Windsor
high-service pump flows)
Windsor high-service pump #1 on [0600 to 2300] at 1,025 gpm)
North Dover elevated storage tank in service: Initial WL=29.0 feet
Holly well #30 on [0000 to 0600], [2000 to 2400] at 1404 gpm, [0600 to
2000] at 2,204 gpm
Parkway well #22 on [0500 to 0700], [1000 to 1900], [2100 to 2200] at
22 gpm, [0700 to 1000] at 4,800 gpm
Parkway well #24 on [0500 to 0700], [1000 to 1900], [2100 to 2200] at
30 gpm, [1900 to 2100] at 4,800 gpm
Parkway well #26 on [0500 to 0700], [1000 to 1900], [2100 to 2200] at
834 gpm
Parkway well #28 on [0500 to 0700], [1000 to 1900], [2100 to 2200] at
869 gpm
Parkway well #29 on [0500 to 0700], [1000 to 1900], [2100 to 2200] at
626 gpm
Parkway well #42 on [0500 to 0700], [1000 to 1900], [2100 to 2200] at
507 gpm
Brookside well #15 on [0000 to 0100] at 411 gpm
Indian Head well #20 on [0000 to 0500] and [2300 to 2400] at 438 gpm
Route 70, well #31 on [0000 to 2400] at 667 gpm
South Toms River well #32 on [0000 to 2400] at 581 gpm
(note: South Toms River well #38 out of service)
Berkeley well #33 on [0000 to 2000] at 873 gpm
Berkeley well #34 on [0000 to 2400] at 939 gpm
Berkeley well #35 on [0000 to 2400] at 652 gpm
Windsor well #40 on [0600 to 2300] at 1,025 gpm
|
|
August
|
Indian Hill elevated storage tank in service: Initial WL=32.0 feet
Holly ground-level storage tank in service (closed in EPANET 2)
(note:Holly wells pump directly into system and represent Holly high-service
pump flows)
Holly high-service pump #1 on [0600 to 2200] at 900 gpm
Holly high-service pump #2 on [0600 to 2200] at 1,300 gpm [0000 to 0600]
and [2000 to 2400] at 1,395 gpm)
Parkway ground-level storage tank in service (closed in EPANET 2)
(note:Parkway wells pump directly into system and represent Parkway
high-service pump flows)
Parkway high-service pump #1 on [0500 to 0600], [1000 to 1800], [2000
to 2200] at 3,078 gpm
Parkway high-service pump #2 on [0600 to 1000] and [1800 to 2000] at 4,800
gpm)
Holiday City ground-level storage tank in service: Initial WL=16.0
Holiday City booster pump off and bypass pipe open [0000 to 0600]
Holiday City booster pump on (set at 0.87) and bypass pipe closed [0600
to 1100]
Holiday City booster pump off and bypass pipe closed [1100 to 2300]
Holiday City booster pump off and bypass pipe open [2300 to 2400]
Windsor ground-level storage tank in service (closed in EPANET 2)
note:Windsor well pumps directly into system and represents Windsor
high-service pump flows)
Windsor high-service pump #1 on [0000 to 2400] at 1,111 gpm)
North Dover elevated storage tank in service: Initial WL=27.0 feet
Holly well #30 on [0000 to 0600] and [2200 to 2400] at 1,395 gpm, [0600
to 2200] at 2,200 gpm
Parkway well #22 on [0500 to 0600], [1000 to 1800], [2000 to 2200] at
288 gpm, [0700 to 0900] at 4,800 gpm
Parkway well #24 on [0500 to 0600], [1000 to 1800], [2000 to 2200] at
360 gpm
Parkway well #26 on [0500 to 0600], [1000 to 1800], [2000 to 2200] at
805 gpm
Parkway well #28 on [0500 to 0600], [1000 to 1800], [2000 to 2200] at
133 gpm, [0900 to 1000] and [1800 to 1900] at 4,800 gpm
Parkway well #29 on [0500 to 0600], [1000 to 1800], [2000 to 2200] at
683 gpm, [1900 to 2000] at 4,800 gpm
Parkway well #42 on [0500 to 0600], [1000 to 1800], [2000 to 2200] at
807 gpm
(note:Brookside well #15 out of service)
(note:Indian Head well #20 out of service)
Route 70, well #31 on [0000 to 2400] at 665 gpm
South Toms River well #32 on [0000 to 2400] at 570 gpm
Berkeley well #33 on [0000 to 2100] at 895 gpm
Berkeley well #34 on [0000 to 2400] at 928 gpm
Berkeley well #35 on [0000 to 2400] at 667 gpm
Windsor well #40 on [0000 to 2400] at 1,111 gpm
|
|
September
|
Indian Hill elevated storage tank in service: Initial WL=36.0 feet
Holly ground-level storage tank in service (closed in EPANET 2)
(note:Holly wells pump directly into system and represent Holly high-service
pump flows)
Holly high-service pump #1 on [0800 to 1500] at 917 gpm
Holly high-service pump #2 on [0000 to 0800] and [1500 to 2400] at 1,418
gpm)
Parkway ground-level storage tank in service (closed in EPANET 2)
(note:Parkway wells pump directly into system and represent Parkway
high-service pump flows)
Parkway high-service pump #1 on [0500 to 0700], [1200 to 1700], [2100
to 2300] at 3,077 gpm
Parkway high-service pump #2 on [0700 to 1200] and [1700 to 2100] at 4,800
gpm)
Holiday City ground-level storage tank in service: Initial WL=16.0
Holiday City booster pump off and bypass pipe open [0000 to 0600]
Holiday City booster pump on (set at 0.87) and bypass pipe closed [0600
to 1100]
Holiday City booster pump off and bypass pipe closed [1100 to 2300]
Holiday City booster pump off and bypass pipe open [2300 to 2400]
Windsor ground-level storage tank in service (closed in EPANET 2)
(note:Windsor well pumps directly into system and represents Windsor
high-service pump flows)
Windsor high-service pump #1 on [0600 to 1700] at 974 gpm)
North Dover elevated storage tank in service: Initial WL=30.0 feet
Holly well #30 on [0000 to 0800] at 1418 gpm, [0800 to 1500] at 917 gpm,
[1500 to 2400] at 1,418 gpm
Parkway well #22 on [0500 to 0700], [1200 to 1700], [2100 to 2300] at
8 gpm, [0700 to 1000] at 4,800 gpm
Parkway well #24 on [0500 to 0700], [1200 to 1700], [2100 to 2300] at
941 gpm
Parkway well #26 on [0500 to 0700], [1200 to 1700], [2100 to 2300] at
67 gpm, [1000 to 1200] at 4,800 gpm
Parkway well #28 on [0500 to 0700], [1200 to 1700], [2100 to 2300] at
247 gpm, [1700 to 1900] at 4,800 gpm
Parkway well #29 on [0500 to 0700], [1200 to 1700], [2100 to 2300] at
981 gpm
Parkway well #42 on [0500 to 0700], [1200 to 1700], [2100 to 2300] at
833 gpm, [1900 to 2100] at 4,800 gpm
Route 70, well #31 on [0000 to 2400] at 657 gpm
South Toms River well #32 on [0000 to 2400] at 624 gpm
Berkeley well #33 on [0000 to 1200] and [1600 to 2400] at 876 gpm
Berkeley well #34 on [0000 to 2400] at 982 gpm
Berkeley well #35 on [0000 to 2400] at 677 gpm
Windsor well #40 on [0600 to 1700] at 974 gpm
|
|
October
(Average-Demand Month)
|
Indian Hill elevated storage tank in service: Initial WL=36.0 feet
Holly ground-level storage tank in service (closed in EPANET 2)
(note:Holly wells pump directly into system and represent Holly high-service
pump flows)
Holly high-service pump #1 on [0800 to 1300] at 940 gpm)
Parkway ground-level storage tank in service (closed in EPANET 2)
(note:Parkway wells pump directly into system and represent Parkway
high-service pump flows)
Parkway high-service pump #1 on [0400 to 0600], [1200 to 1700], [2200
to 2400] at 2,949 gpm
Parkway high-service pump #2 on [0600 to 1200] and [1700 to 2200] at 4,800
gpm)
Holiday City ground-level storage tank in service: Initial WL=17.0
Holiday City booster pump off and bypass pipe open [0000 to 0600]
Holiday City booster pump on (set at 0.87) and bypass pipe closed [0600
to 1100]
Holiday City booster pump off and bypass pipe closed [1100 to 2300]
Holiday City booster pump off and bypass pipe open [2300 to 2400]
(note:Windsor ground-level storage tank out of service)
North Dover elevated storage tank in service: Initial WL=33.0 feet
Holly well #30 on [0800 to 1300] at 940 gpm
Parkway well #22 on [0400 to 0600], [1200 to 1700] and [2200 to 2400]
at 530 gpm, [0600 to 0800] at 4,800 gpm
Parkway well #24 on [0400 to 0600], [1200 to 1700], [2200 to 2400] at
35 gpm, [0800 to 1000] at 4,800 gpm
Parkway well #26 on [0400 to 0600], [1200 to 1700], [2200 to 2400] at
77 gpm, [1000 to 1200] at 4,800 gpm
Parkway well #28 on [0400 to 0600], [1200 to 1700], [2200 to 2400] at
1,320 gpm
Parkway well #29 on [0400 to 0600], [1200 to 1700], [2200 to 2400] at
946 gpm
Parkway well #42 on [0400 to 0600], [1200 to 1700], [2200 to 2400] at
40 gpm, [1700 to 2200] at 4,800 gpm
Route 70, well #31 on [0000 to 2400] at 666 gpm
South Toms River well #32 on [0000 to 2400] at 591 gpm
Berkeley well #33 on [0000 to 1300] and [1600 to 2400] at 879 gpm
Berkeley well #34 on [0000 to 2400] at 1,010 gpm
Berkeley well #35 on [0000 to 2400] at 695 gpm
|
|
November
|
Indian Hill elevated storage tank in service: Initial WL=23.0 feet
Holly ground-level storage tank in service (closed in EPANET 2)
(note:Holly wells pump directly into system and represent Holly high-service
pump flows)
Holly high-service pump #1 on [0000 to 2400] at 913 gpm)
Parkway ground-level storage tank in service (closed in EPANET 2)
(note:Parkway wells pump directly into system and represent Parkway
high-service pump flows)
Parkway high-service pump #1 on [0900 to 2100] at 2,883 gpm)
Holiday City ground-level storage tank in service: Initial WL=16.0
Holiday City booster pump off and bypass pipe open [0000 to 0600]
Holiday City booster pump on (set at 0.87) and bypass pipe closed [0600
to 1100]
Holiday City booster pump off and bypass pipe closed [1100 to 2300]
Holiday City booster pump off and bypass pipe open [2300 to 2400]
Windsor ground-level storage tank in service (closed in EPANET 2)
(note:Windsor well pumps directly into system and represents Windsor
high-service pump flows)
Windsor high-service pump #1 on [0300 to 2300] at 1,014 gpm)
North Dover elevated storage tank in service: Initial WL=26.0 feet
Holly well #30 on [0000 to 2400] at 913 gpm
Parkway well #22 on [0900 to 2100] at 523 gpm
Parkway well #24 on [0900 to 2100] at 369 gpm
Parkway well #26 on [0900 to 2100] at 375 gpm
Parkway well #28 on [0900 to 2100] at 426 gpm
Parkway well #29 on [0900 to 2100] at 314 gpm
Parkway well #42 on [0900 to 2100] at 875 gpm
Route 70, well #31 on [0000 to 2400] at 674 gpm
South Toms River well #32 on [0700 to 2000] at 542 gpm
Berkeley well #33 on [0000 to 1200] and [1600 to 2400] at 895 gpm
Berkeley well #34 on [0000 to 2400] at 952 gpm
Berkeley well #35 on [0400 to 2200] at 629 gpm
Windsor well #40 on [0300 to 2300] at 1,014 gpm
|
|
December
|
Indian Hill elevated storage tank in service: Initial WL=12.0 feet
Holly ground-level storage tank in service (closed in EPANET 2)
(note:Holly wells pump directly into system and represent Holly high-service
pump flows)
Holly high-service pump #1 on [0600 to 1900] at 900 gpm
Holly high-service pump #2 on [0600 to 1900] at 1,315 gpm, [0000 to 0600]
and [1900 to 2400] at 1,415 gpm)
Parkway ground-level storage tank in service (closed in EPANET 2)
Holiday City ground-level storage tank in service: Initial WL=16.0
Holiday City booster pump off and bypass pipe open [0000 to 0600]
Holiday City booster pump on (set at 0.87) and bypass pipe closed [0600
to 1100]
Holiday City booster pump off and bypass pipe closed [1100 to 2300]
Holiday City booster pump off and bypass pipe open [2300 to 2400]
Windsor ground-level storage tank in service (closed in EPANET 2)
(note:Windsor well pumps directly into system and represents Windsor
high-service pump flows)
Windsor high-service pump #1 on [0000 to 0600] and [2000 to 2400] at 1,049
gpm, [0600 to 2000] at 1,100 gpm)
Windsor high-service pump #3 on [0600 to 2000] at 1,100 gpm
North Dover elevated storage tank in service: Initial WL=10.0 feet
Holly well #30 on [0000 to 0600] and [1900 to 2400] at 1,415 gpm, [0600
to 1900] at 2,215 gpm
(note:Parkway well #22 out of service)
(note:Parkway well #24 out of service)
(note:Parkway well #26 out of service)
(note:Parkway well #28 out of service)
(note:Parkway well #29 out of service)
(note:Parkway well #42 out of service)
Route 70, well #31 on [0000 to 2400] at 674 gpm
(note: South Toms River well #32 out of service)
Berkeley well #33 on [0000 to 1300] and [1500 to 2400] at 901 gpm
Berkeley well #34 on [0000 to 2400] at 1,035 gpm
(note:Berkeley well #35 out of service)
Windsor well #40 on [0000 to 0600] and [2000 to 2400] at 1,049 gpm, [0600
to 2000] at 2,200 gpm
|